{"id":500,"date":"2020-06-03T09:53:25","date_gmt":"2020-06-03T02:53:25","guid":{"rendered":"https:\/\/demo1.x-zel.com\/?post_type=product&p=500"},"modified":"2020-06-05T10:48:34","modified_gmt":"2020-06-05T03:48:34","slug":"module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00","status":"publish","type":"product","link":"https:\/\/x-zel.com\/san-pham\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/","title":{"rendered":"Module Output R\u1edd le \u0111i\u1ec1u khi\u1ec3n VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00"},"content":{"rendered":"

Dual Relay Modules
VF6052-00 (Low Voltage), VF6053-00 (Low Voltage w\/ Isolator),
VF6054-00 (High Voltage), VF6055-00 (High Voltage w\/ Isolator)<\/span> \u00a0 \u00a0\u00a0
<\/span><\/span><\/h2><\/td><\/tr><\/tbody><\/table>
Standard Features<\/span> <\/strong><\/span>
\u2022 Provides two independently configurable Form C contacts per address
\u2022 Contacts are rated as follow:
\u2022 VF6052\/ VF6053: 2A @ 30 VDC \/ 0.5A @ 120 VAC
\u2022 VF6054\/ VF6055: 8A @ 30VDC \/ 4.8A @ 250 VAC
\u2022 Up to127 devices can be used on each SLC loop
\u2022 Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on when activated. (For All Models)
\u2022 Yellow LED indicates a short circuit condition (VF6053 and VF6055 only)
\u2022 Programming is highly flexible providing 16 priority states plus zoning capability
\u2022 Operates on Class A or Class B SLC loop
<\/span><\/strong>

Technical Specifications<\/strong><\/span><\/p><\/td><\/tr><\/tbody><\/table>
Supply Voltage Nominal <\/span><\/td>25.3-39 VDC<\/span><\/td><\/tr>
Average Current Consumption<\/span><\/td>350<\/span>\u03bc<\/span>A (typical)
405<\/span>\u03bc<\/span>A (alarm)<\/span><\/td><\/tr>
Contacts <\/span><\/td>2 Independently Controlled Form C
<\/span>VF6052\/VF6053
<\/span>2A @ 30 VDC\/ 0.5A @ 120 VAC
<\/span>VF6054\/VF6055
<\/span>8A @ 30 VDC\/ 4.8A @ 250 VAC<\/span><\/td><\/tr>
SCI on Resistance <\/span><\/td>40 ohm max (normal condition)<\/span><\/td><\/tr>
SCI Fault Detection Threshold <\/span><\/td>12 Volts (typical)<\/span><\/td><\/tr>
SCI Isolation Current (Short Circuit Condition)<\/span><\/td>10 mA (typical)<\/span><\/td><\/tr>
Maximum Quantity per Loop <\/span><\/td>127<\/span><\/td><\/tr>
Mounting <\/span><\/td>4\u201d Square Electrical Box<\/span><\/td><\/tr>
Maximum Humidity <\/span><\/td>up to 90%, non-condensing<\/span><\/td><\/tr>
UL Ambient Installation
Temperature Range<\/span><\/td>
32<\/span>\u00ba <\/span>F to 120<\/span>\u00ba <\/span>F<\/span><\/td><\/tr>
Dimensions <\/span><\/td>4.2\u201d W x 4.7\u201d H x 1.4\u201d D<\/span><\/td><\/tr><\/tbody><\/table>","protected":false},"excerpt":{"rendered":"

The Dual Relay Modules have been designed to provide flexible and quick response to emergency conditions. The VES Series allows independent control of two form C contacts for a variety of normally open and normally closed contact applications such as fan operation, elevator recall, door closure, and auxiliary notification.
Each VES Series module provides independent control of two Form C contacts while utilizing one SLC (Signaling Line Circuit) address. The modules have a highly configurable programming algorithm that allows the user to set up groups of devices (zoning) for simultaneous operation of multiple VF6052, VF6053, VF6054, and VF6055 modules. The operating parameters are maintained by the module and do not require individual communication with the control panel during the emergency condition to operate. The control panel broadcasts the control command on the SLC loop and the VES Series modules do the rest based on their custom configuration. Since mechanically latching relays are used within the VES Series modules, a separate 24VDC power source is not required.<\/p>\n

\u21d3 T\u1ea3i xu\u1ed1ng Catalogue VF6052|VF6053|VF6054|VF6055<\/a>
<\/span><\/p>\n","protected":false},"featured_media":502,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"yst_prominent_words":[],"aioseo_notices":[],"yoast_head":"\nModule Output R\u1edd le \u0111i\u1ec1u khi\u1ec3n VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 - C\u00f4ng ty TNHH Mela<\/title>\n<meta name=\"robots\" content=\"index, follow\" \/>\n<meta name=\"googlebot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"bingbot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/\" \/>\n<meta property=\"og:locale\" content=\"vi_VN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Module Output R\u1edd le \u0111i\u1ec1u khi\u1ec3n VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 - C\u00f4ng ty TNHH Mela\" \/>\n<meta property=\"og:description\" content=\"The Dual Relay Modules have been designed to provide flexible and quick response to emergency conditions. The VES Series allows independent control of two form C contacts for a variety of normally open and normally closed contact applications such as fan operation, elevator recall, door closure, and auxiliary notification.Each VES Series module provides independent control of two Form C contacts while utilizing one SLC (Signaling Line Circuit) address. The modules have a highly configurable programming algorithm that allows the user to set up groups of devices (zoning) for simultaneous operation of multiple VF6052, VF6053, VF6054, and VF6055 modules. The operating parameters are maintained by the module and do not require individual communication with the control panel during the emergency condition to operate. The control panel broadcasts the control command on the SLC loop and the VES Series modules do the rest based on their custom configuration. Since mechanically latching relays are used within the VES Series modules, a separate 24VDC power source is not required.\u21d3 T\u1ea3i xu\u1ed1ng Catalogue VF6052|VF6053|VF6054|VF6055\" \/>\n<meta property=\"og:url\" content=\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/\" \/>\n<meta property=\"og:site_name\" content=\"C\u00f4ng ty TNHH Mela\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/VESfiredetection\" \/>\n<meta property=\"article:modified_time\" content=\"2020-06-05T03:48:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/x-zel.com\/wp-content\/uploads\/2020\/06\/MODULE-OUTPUT-R\u1edc-LE-\u0110I\u1ec0U-KHI\u1ec2N-VF6052-VF6053-VF6054-VF6055.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/x-zel.com\/#organization\",\"name\":\"C\\u00f4ng ty TNHH Melaco\",\"url\":\"https:\/\/x-zel.com\/\",\"sameAs\":[\"https:\/\/www.facebook.com\/VESfiredetection\"],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/x-zel.com\/#logo\",\"inLanguage\":\"vi\",\"url\":\"https:\/\/x-zel.com\/wp-content\/uploads\/2020\/06\/logo-melaco-01.png\",\"width\":1304,\"height\":1341,\"caption\":\"C\\u00f4ng ty TNHH Melaco\"},\"image\":{\"@id\":\"https:\/\/x-zel.com\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/x-zel.com\/#website\",\"url\":\"https:\/\/x-zel.com\/\",\"name\":\"C\\u00f4ng ty TNHH Mela\",\"description\":\"Nh\\u00e0 ph\\u00e2n ph\\u1ed1i thi\\u1ebft b\\u1ecb PCCC\",\"publisher\":{\"@id\":\"https:\/\/x-zel.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/x-zel.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"vi\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/#primaryimage\",\"inLanguage\":\"vi\",\"url\":\"https:\/\/x-zel.com\/wp-content\/uploads\/2020\/06\/MODULE-OUTPUT-R\\u1edc-LE-\\u0110I\\u1ec0U-KHI\\u1ec2N-VF6052-VF6053-VF6054-VF6055.png\",\"width\":500,\"height\":500,\"caption\":\"MODULE OUTPUT R\\u1edc LE \\u0110I\\u1ec0U KHI\\u1ec2N VF6052-VF6053-VF6054-VF6055\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/#webpage\",\"url\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/\",\"name\":\"Module Output R\\u1edd le \\u0111i\\u1ec1u khi\\u1ec3n VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 - C\\u00f4ng ty TNHH Mela\",\"isPartOf\":{\"@id\":\"https:\/\/x-zel.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/#primaryimage\"},\"datePublished\":\"2020-06-03T02:53:25+00:00\",\"dateModified\":\"2020-06-05T03:48:34+00:00\",\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00\/\"]}]}]}<\/script>\n","_links":{"self":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/product\/500"}],"collection":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/comments?post=500"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/media\/502"}],"wp:attachment":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/media?parent=500"}],"wp:term":[{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/yst_prominent_words?post=500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}