{"id":497,"date":"2020-06-03T09:45:05","date_gmt":"2020-06-03T02:45:05","guid":{"rendered":"https:\/\/demo1.x-zel.com\/?post_type=product&p=497"},"modified":"2020-06-05T10:43:01","modified_gmt":"2020-06-05T03:43:01","slug":"module-input-giam-sat-doi-2-ngo-vao-vf6007-00","status":"publish","type":"product","link":"https:\/\/x-zel.com\/san-pham\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/","title":{"rendered":"Module Input Gi\u00e1m s\u00e1t \u0111\u00f4i (2 ng\u00f5 v\u00e0o) VF6007-00"},"content":{"rendered":"

Dual Input Monitor Modules
VF6007-00<\/span> \u00a0 \u00a0
<\/span><\/span><\/h2><\/td><\/tr><\/tbody><\/table>
Standard Features<\/span> <\/strong><\/span>
\u2022 Fast, reliable contact monitoring utilizing the VES DCP (Digital Communications Protocol)
\u2022 127 devices can be used per DCP loop
\u2022 Bi-colored indicating LED provides module status
\u2022 Dual input contact monitor
\u2022 Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
\u2022 Operates on Class A or Class B SLC loop
\u2022 Accepts up to 14 AWG wire
\u2022 Mounts to 4\u201d square gang box

Application<\/span>
<\/span><\/strong>The VES VF6007 provides installing dealers an economical approach <\/span>to monitor devices in the same proximity, such as water flow and valve supervision on the same interface device.
This capability when coupled with VES\u2019s SIA DACT transmission provides sub-point reporting for complete annunciation and accurate reporting to responders and users.
VES\u2019s reporting approach is superior in that the capability to accurately report dissimilar inputs, such as alarm and supervisory are present.<\/span>

<\/span><\/strong>

Technical Specifications<\/strong><\/span><\/p><\/td><\/tr><\/tbody><\/table>
Operating Voltage <\/span><\/td>17-41 VDC<\/span><\/td><\/tr>
Average Current Consumption <\/span><\/td>600<\/span>\u03bc<\/span>A (Typical)<\/span><\/td><\/tr>
Alarm Current <\/span><\/td>30 mA<\/span><\/td><\/tr>
Maximum Quantity per Loop <\/span><\/td>127<\/span><\/td><\/tr>
Mounting <\/span><\/td>4\u201d Square Electrical Box<\/span><\/td><\/tr>
Maximum Humidity <\/span><\/td>up to 90%, non-condensing<\/span><\/td><\/tr>
UL Ambient Installation
Temperature Range<\/span><\/td>
32<\/span>\u00ba <\/span>F to 120<\/span>\u00ba <\/span>F<\/span><\/td><\/tr>
Dimensions <\/span><\/td>4.2\u201d W x 4.7\u201d H x 1.4\u201d D<\/span><\/td><\/tr><\/tbody><\/table>","protected":false},"excerpt":{"rendered":"

The VES Dual Monitor Module (VF6007) is designed for use on the Elite analog addressable system. It provides two independent contact monitoring circuits while only utilizing one address on the SLC loop.
Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM. The module can be programmed to monitor normally open (NO) or normally closed (NC) contact fire alarm and supervisory devices.
The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions.
The module has a single bi-colored LED to indicate device status. It fits into a standard 4\u201d square or double gang electrical back box.<\/p>\n

\u21d3 T\u1ea3i xu\u1ed1ng Catalogue VF6007<\/a>
<\/span><\/p>\n","protected":false},"featured_media":499,"comment_status":"open","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"yst_prominent_words":[],"aioseo_notices":[],"yoast_head":"\nModule Input Gi\u00e1m s\u00e1t \u0111\u00f4i (2 ng\u00f5 v\u00e0o) VF6007-00 - C\u00f4ng ty TNHH Mela<\/title>\n<meta name=\"robots\" content=\"index, follow\" \/>\n<meta name=\"googlebot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"bingbot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/\" \/>\n<meta property=\"og:locale\" content=\"vi_VN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Module Input Gi\u00e1m s\u00e1t \u0111\u00f4i (2 ng\u00f5 v\u00e0o) VF6007-00 - C\u00f4ng ty TNHH Mela\" \/>\n<meta property=\"og:description\" content=\"The VES Dual Monitor Module (VF6007) is designed for use on the Elite analog addressable system. It provides two independent contact monitoring circuits while only utilizing one address on the SLC loop.Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM. The module can be programmed to monitor normally open (NO) or normally closed (NC) contact fire alarm and supervisory devices.The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions.The module has a single bi-colored LED to indicate device status. It fits into a standard 4\u201d square or double gang electrical back box.\u21d3 T\u1ea3i xu\u1ed1ng Catalogue VF6007\" \/>\n<meta property=\"og:url\" content=\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/\" \/>\n<meta property=\"og:site_name\" content=\"C\u00f4ng ty TNHH Mela\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/VESfiredetection\" \/>\n<meta property=\"article:modified_time\" content=\"2020-06-05T03:43:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/x-zel.com\/wp-content\/uploads\/2020\/06\/MODULE-INPUT-GI\u00c1M-S\u00c1T-\u0110\u00d4I-VF6007.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/x-zel.com\/#organization\",\"name\":\"C\\u00f4ng ty TNHH Melaco\",\"url\":\"https:\/\/x-zel.com\/\",\"sameAs\":[\"https:\/\/www.facebook.com\/VESfiredetection\"],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/x-zel.com\/#logo\",\"inLanguage\":\"vi\",\"url\":\"https:\/\/x-zel.com\/wp-content\/uploads\/2020\/06\/logo-melaco-01.png\",\"width\":1304,\"height\":1341,\"caption\":\"C\\u00f4ng ty TNHH Melaco\"},\"image\":{\"@id\":\"https:\/\/x-zel.com\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/x-zel.com\/#website\",\"url\":\"https:\/\/x-zel.com\/\",\"name\":\"C\\u00f4ng ty TNHH Mela\",\"description\":\"Nh\\u00e0 ph\\u00e2n ph\\u1ed1i thi\\u1ebft b\\u1ecb PCCC\",\"publisher\":{\"@id\":\"https:\/\/x-zel.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/x-zel.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"vi\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/#primaryimage\",\"inLanguage\":\"vi\",\"url\":\"https:\/\/x-zel.com\/wp-content\/uploads\/2020\/06\/MODULE-INPUT-GI\\u00c1M-S\\u00c1T-\\u0110\\u00d4I-VF6007.png\",\"width\":500,\"height\":500,\"caption\":\"MODULE INPUT GI\\u00c1M S\\u00c1T \\u0110\\u00d4I VF6007\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/#webpage\",\"url\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/\",\"name\":\"Module Input Gi\\u00e1m s\\u00e1t \\u0111\\u00f4i (2 ng\\u00f5 v\\u00e0o) VF6007-00 - C\\u00f4ng ty TNHH Mela\",\"isPartOf\":{\"@id\":\"https:\/\/x-zel.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/#primaryimage\"},\"datePublished\":\"2020-06-03T02:45:05+00:00\",\"dateModified\":\"2020-06-05T03:43:01+00:00\",\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/x-zel.com\/shop\/thiet-bi-bao-chay-ves\/bao-chay-dia-chi\/module-dia-chi\/module-input-giam-sat-doi-2-ngo-vao-vf6007-00\/\"]}]}]}<\/script>\n","_links":{"self":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/product\/497"}],"collection":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/comments?post=497"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/media\/499"}],"wp:attachment":[{"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/media?parent=497"}],"wp:term":[{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/x-zel.com\/wp-json\/wp\/v2\/yst_prominent_words?post=497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}