Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com Nhà phân phối thiết b?PCCC Mon, 30 Nov 2020 02:13:54 +0000 vi hourly 1 //wordpress.org/?v=6.2.3 //x-zel.com/wp-content/uploads/2021/11/New-Melaco-fire-protection-logo-81x81.png Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com 32 32 Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/bo-vo-hieu-hoa-phun-khi-as1832-10/?utm_source=rss&utm_medium=rss&utm_campaign=bo-vo-hieu-hoa-phun-khi-as1832-10 //x-zel.com/san-pham/bo-vo-hieu-hoa-phun-khi-as1832-10/#respond Sat, 07 Nov 2020 04:32:26 +0000 //x-zel.com/?post_type=product&p=1641 ?Key removable in either position
?Both sides of solenoid circuit are mechanically disabled during activation
?Disablement illuminated at panel when active
?Tải xuống Catalogue

The post B?vô hiệu hóa phun khí AS1832-10 first appeared on Công ty TNHH Mela.

Bài viết B?vô hiệu hóa phun khí AS1832-10 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Releasing System Peripherals
Disablement Switch  


Standard Features
?Key removable in either position
?Both sides of solenoid circuit are mechanically disabled during activation
?Disablement illuminated at panel when active

Ordering Codes

AS1832-10Disablement Switch (red)

The post B?vô hiệu hóa phun khí AS1832-10 first appeared on Công ty TNHH Mela.

Bài viết B?vô hiệu hóa phun khí AS1832-10 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/bo-vo-hieu-hoa-phun-khi-as1832-10/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/cong-tac-phun-khi-as3045-56/?utm_source=rss&utm_medium=rss&utm_campaign=cong-tac-phun-khi-as3045-56 //x-zel.com/san-pham/cong-tac-phun-khi-as3045-56/#respond Sat, 07 Nov 2020 04:32:23 +0000 //x-zel.com/?post_type=product&p=1640 Conventional Manual Pull Stations available in a number of configurations supporting Fire Alarm & Fire Suppression System.
Each model is constructed of a solid die cast housing and comes in glossy red. The back switch plate is plated steel. The electrical switch is rated for 10 Amps @ 120 VDC normally open contact rating. Most models are connected via terminal block connections (see ordering codes on second page)
?Tải xuống Catalogue

The post Công tắc phun khí AS3045-56 first appeared on Công ty TNHH Mela.

Bài viết Công tắc phun khí AS3045-56 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Conventional Devices
Manual Non-Coded Pull Station for Fire & Releasing Applications


Standard Features
?Single or Dual Action
?Enclosed switch with glass rod (included)
?10 Amps @ 120 VAC Snap Action Switch
?Made in USA


Ordering Codes

AS3045-56Conventional Pull Station for Fire Suppression Release – Yellow DPST

Technical Specifications

Contact Rating10A @ 120 VAC
Operating Temperature-30°F (-35 °C) ~ 150°F (66°C)

The post Công tắc phun khí AS3045-56 first appeared on Công ty TNHH Mela.

Bài viết Công tắc phun khí AS3045-56 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/cong-tac-phun-khi-as3045-56/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/thiet-bi-dung-phun-khi-as1823-10/?utm_source=rss&utm_medium=rss&utm_campaign=thiet-bi-dung-phun-khi-as1823-10 //x-zel.com/san-pham/thiet-bi-dung-phun-khi-as1823-10/#respond Sat, 07 Nov 2020 04:32:18 +0000 //x-zel.com/?post_type=product&p=1639 The Supreme Abort switch connects to the Abort terminals of the Supreme XT releasing panel. Any number of Supreme Abort switches may be connected to the circuit. The last switch must have the end of line device from the Abort circuit terminals of the Supreme XT releasing panel fitted across its connections to provide open and short circuit supervision.
The unit is supplied mounted to a rugged steel enclosure but may also be flush mounted to a single gang electrical box.
?Tải xuống Catalogue

The post Thiết b?dừng phun khí AS1823-10 first appeared on Công ty TNHH Mela.

Bài viết Thiết b?dừng phun khí AS1823-10 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Releasing System Peripherals
Abort Switch  


The Supreme Abort switch connects to the Abort terminals of the Supreme XT releasing panel. Any number of Supreme Abort switches may be connected to the circuit. The last switch must have the end of line device from the Abort circuit terminals of the Supreme XT releasing panel fitted across its connections to provide open and short circuit supervision.
The unit is supplied mounted to a rugged steel enclosure but may also be flush mounted to a single gang electrical box.


Ordering Codes

AS1823-10Supreme Extinguishing Abort switch surface mount – red

Technical Specifications

Size 3.81?(W) x 3.81?(H) x 2.32?(D)
Color Standard red or gray
Switch Rating 1A at 30V
Trigger Resistor 470R 1W
End-of-Line Resistor 6K8 1/2 W

The post Thiết b?dừng phun khí AS1823-10 first appeared on Công ty TNHH Mela.

Bài viết Thiết b?dừng phun khí AS1823-10 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/thiet-bi-dung-phun-khi-as1823-10/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-dieu-khien-chua-chay-dia-chi-supreme-xt-as0891-10-as0892-10/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-dieu-khien-chua-chay-dia-chi-supreme-xt-as0891-10-as0892-10 //x-zel.com/san-pham/trung-tam-dieu-khien-chua-chay-dia-chi-supreme-xt-as0891-10-as0892-10/#respond Sat, 07 Nov 2020 04:32:15 +0000 //x-zel.com/?post_type=product&p=1638 XT+ control panels are multi-area releasing control modules complying with UL 864 10th Edition.
Up to 15 releasing modules may be connected to a master fire alarm control panel. Each releasing module can accommodate a separate hazard defined by two specific zone.
Each XT+ unit is equipped with a 5.25 A power supply (120 VAC or 240 VAC) to power releasing modules and attached solenoids / actuators.
Each releasing area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface. All releasing areas may have up to 7 serially-connected status indication and control units or ancillary relay boards.
?Tải xuống Catalogue

The post Trung tâm điều khiển chữa cháy địa ch?SUPREME XT+ AS0891-10 | AS0892 ?10 first appeared on Công ty TNHH Mela.

Bài viết Trung tâm điều khiển chữa cháy địa ch?SUPREME XT+ AS0891-10 | AS0892 – 10 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

XT+ | Multi-Area Addressable Releasing Control Units
NOTE This unit must be connected to an Elite RS panel.
    


Standard Features
?UL 864 10th Edition Listed
?Up to 2 releasing areas / hazards per XT+ unit
?Dual releasing outputs for each area (configurable as Main/Reserve)
?First and second stage NAC outputs for each area
?First and second stage volt free changeover relays for each area
?Released volt-free relay per area
?Trouble volt-free relay per area
?Programmable releasing delays
?Programmable output duration
?Countdown indicator shows time until release in seconds
?Mode select and manual release controls per area
?Monitored remote manual release input
?Monitored remote abort input
?Monitored remote mode select input
?Monitored remote released pressure switch input
?Serial connections for status units and ancillary boards


Releasing Module Cabinets

AS0891-10 1 Area, Red
AS0891-40 1 Area, Gray
AS0892-10 2 Area, Red
AS0892-40 2 Area, Gray
All cabinets are equipped with a 5.25A Power Supply.

Technical Specifications

Construction 1.2mm mild sheet steel
IP Rating IP30
Finish Epoxy powder coated
Color Lid & Box
Gray – BS 00 A 05
Red – RAL 3002
Fascia
RAL 7016
Weight 17.6 lbs (Standard Configuration)
Cabling FP200 or equivalent (max capacitance 1uF max inductance 1 mH)
Power Supply 1.83A Max @ 120 V, 50/60 Hz
0.915A Max @ 240 V, 50/60 Hz
Power Supply Fuse 3A
Power Supply Rating 1 and 2 Area Units: Regulated 24V DC @ 4A
Maximum Ripple Current 1V Maximum
Battery Charge Voltage 27.6VDC nominal (temperature compensated)
Battery Fuse 10A 3AG
Current Draw in Power Fail Condition 54mA per releasing module
Max Current Draw from Batteries 4A
Ground Fault Impedance Value 100 Ohms
Temperature Range 32ºF – 120ºF (0ºC – 49ºC)
Relative Humidity up to 93%, non-condensing
Releasing Delay Adjustable 0 to 60 seconds (+/- 10%)
Releasing Duration Adjustable 60 to 300 seconds

The post Trung tâm điều khiển chữa cháy địa ch?SUPREME XT+ AS0891-10 | AS0892 ?10 first appeared on Công ty TNHH Mela.

Bài viết Trung tâm điều khiển chữa cháy địa ch?SUPREME XT+ AS0891-10 | AS0892 – 10 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-dieu-khien-chua-chay-dia-chi-supreme-xt-as0891-10-as0892-10/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/bo-hien-thi-chua-chay-khi-as1821-13/?utm_source=rss&utm_medium=rss&utm_campaign=bo-hien-thi-chua-chay-khi-as1821-13 //x-zel.com/san-pham/bo-hien-thi-chua-chay-khi-as1821-13/#respond Sat, 07 Nov 2020 04:32:10 +0000 //x-zel.com/?post_type=product&p=1637 The Elite Status Indicators range of status indicators provide detailed status information for Supreme XT releasing control equipment.
All models provide high brightness, LED indication of Manual Only, Automatic and Manual, Abort operated, Disabled, Imminent and Released conditions.
For systems where local control of the Automatic/Manual mode control are required, units are available with these controls fitted. All models have supervised inputs for the remote connection of abort switches. All units contain a large, LED display which shows a countdown of the time remaining until release in seconds.
?Tải xuống Catalogue

The post B?hiển th?chữa cháy khí AS1821-13 first appeared on Công ty TNHH Mela.

Bài viết B?hiển th?chữa cháy khí AS1821-13 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Releasing System Peripherals
Status Indicators


Standard Features
?UL 864
?High brightness LEDs
?Detailed indication of the status of the control panel
?Supervised data connection
?Countdown timer shows time remaining until release
?Manual only and Automatic & Manual mode select keyswitch option
?Four wire connection (data and power)
?Robust, high quality enclosure
?Easy access to terminals
?Remote Abort input (supervised)
?Internal trouble diagnosis indicators

Ordering Codes

AS1821-136 lamp status indicator w/ mode select keyswitch surface mount – red

Technical Specifications

Size 7.3?(W) x 5.2?(H) x 1.9?(D)
Power Supply 21 to 30 V
Maximum Current Draw 0.07A
Maximum Number of Status Units 7
Quiescent Current 0.033A
Cable Capacity 12 AWG
Supervised Inputs End-of-Line Resistor 6K8 0.5W Resistor
Supervised Inputs Normal Impedance 6.8K
Supervised Inputs Trigger Impedance 470 Ohms
Supervised Inputs Short Circuit Threshold 99 Ohms to 0 Ohms
Data connection Two wire RS485 connection (max 4000 feet)

The post B?hiển th?chữa cháy khí AS1821-13 first appeared on Công ty TNHH Mela.

Bài viết B?hiển th?chữa cháy khí AS1821-13 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/bo-hien-thi-chua-chay-khi-as1821-13/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-dieu-khien-chua-chay-supreme-xt-as1810-11/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-dieu-khien-chua-chay-supreme-xt-as1810-11 //x-zel.com/san-pham/trung-tam-dieu-khien-chua-chay-supreme-xt-as1810-11/#respond Sat, 07 Nov 2020 04:32:06 +0000 //x-zel.com/?post_type=product&p=1636 TRUNG TÂM ĐIỀU KHIỂN CHỮA CHÁY Supreme XT AS1810-11 (3 VÙNG BÁO CHÁY - 1 VÙNG CHỮA CHÁY)

Designed and manufactured to the highest standards in a quality controlled environment and with UL and FM approvals, the Supreme XT releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations. With three detection zones as standard, release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any two from three type activations such as would be required for detection in ceiling void, room and floor void applications.
The extensive configuration options of the Supreme XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status.
With all of the electronics mounted on a single, easily removable, steel plate Supreme XT panels are both robust and easy to install. Supreme XT is supplied in an enclosure that matches the design and color of the Supreme CP range and is available in standard red or optional gray.
?Tải xuống Catalogue

The post Trung tâm điều khiển chữa cháy SUPREME XT AS1810-11 first appeared on Công ty TNHH Mela.

Bài viết Trung tâm điều khiển chữa cháy SUPREME XT AS1810-11 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

SUPREME XT
Releasing Fire Control Panels    


Standard Features
?UL 864
?Three detection zones as standard
?Any single zone or any combinations of zones can be configured to release
?Configurable first stage NAC delays
?Configurable detection delays
?Zero time delay upon manual release option
?Non-latching zone input option to receive signals from other systems such as aspirating equipment
?Configurable releasing delays up to 60 seconds in 5 second steps
?Configurable releasing duration up to 5 minutes in 5 second steps
?Countdown timer shows time remaining until release
?Supports up to seven, four wire status indicators
?Built in Extract Fan control
?Compatible with conventional detectors from Apollo, Hochiki America, and System Sensor

Ordering Codes

AS1810-10 Supreme XT – Red 120V
AS1810-11 Supreme XT – Red 240V
AS1810-40 Supreme XT – Gray 120V
AS1810-41 Supreme XT – Gray 240V

Technical Specifications

AC Supply 120V or 240V
AC Supply Fuse 3.15A (F3.15A L250V)
Finish Epoxy powder coated
Color Red (optional gray)
Power Supply Rating 3 Amps total including battery charge 28V ± 2V
Maximum Ripple Voltage 200 millivolts
Battery Type Two 12 Volt 7Ah sealed lead acid in series
Battery Charge Voltage 27.6VDC nominal (temperature-compensated)
Battery Charge Current 0.7A maximum
Battery Fuse 20mm, 3.15A glass Sloblow
Maximum Current Draw from Batteries 3A
Quiescent Current of Panel in Power Failure 0.095A
AUX 24V Output Fused at 500mA with electronic fuse
NAC Outputs 24V Fused at 500mA with electronic fuse
Trouble Relay Contact Rating 30VDC 1A Amp maximum
Fire Relay Contact Rating 30VDC 1A Amp maximum
Local Fire Relay Contact Rating 30VDC 1A Amp maximum
First Stage Contact Rating 30VDC 1A Amp maximum
Second Stage Contact Rating 30VDC 1A Amp maximum
Extract Contact Rating 30VDC 1A Amp maximum
Zone Quiescent Current 2mA maximum
Terminal Capacity 12 AWG
No. of detectors per zone Dependent on type (maximum 32)
Detection circuit end of line 6K8 5% ½ Watt resistor
Supervised input end of line 6K8 5% ½ Watt resistor
Extinguishant output EOL 1N4004 Diode
No. of detection circuits 3
No. of sounder circuits 2 x 1st Stage, 1 x 2nd Stage
Extinguishant release output Rated at 1 Amp
Extinguishant release delay Adjustable 0 to 60 seconds (in 5 second steps)
Extinguishant release duration Adjustable 60 to 300 seconds (in 5 second steps)
Normal Zone Impedance (EOL) 6.8K
Detector Alarm Impedance 470 Ohms
Pull Station Alarm Impedance 270 Ohms
Short circuit threshold Short circuit Impedance 99 Ohms
Supervised Inputs Normal Impedance (EOL) 6.8K
Supervised Inputs Alarm Impedance 470 Ohms
Supervised inputs Short circuit threshold 99 Ohms
Status unit/Ancillary board connection Two wire RS485 connection
Status unit power output Rated at 500mA with electronic fuse

The post Trung tâm điều khiển chữa cháy SUPREME XT AS1810-11 first appeared on Công ty TNHH Mela.

Bài viết Trung tâm điều khiển chữa cháy SUPREME XT AS1810-11 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-dieu-khien-chua-chay-supreme-xt-as1810-11/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/bo-hien-thi-phu-oasis/?utm_source=rss&utm_medium=rss&utm_campaign=bo-hien-thi-phu-oasis //x-zel.com/san-pham/bo-hien-thi-phu-oasis/#respond Sat, 07 Nov 2020 04:00:55 +0000 //x-zel.com/?post_type=product&p=1619 The OASIS Network Vision Annunciator is the most
qualified annunciator on the market. It is a full-color
graphical display and touchscreen. It represents the
most versatile annunciator for life safety systems
available today. The Annunciator is a full-function fire
alarm repeater that is configurable and applicationflexible for use in applications such as hospital nursing
stations and elevator alarms.
?Tải xuống Catalogue

The post B?hiển th?ph?OASIS first appeared on Công ty TNHH Mela.

Bài viết B?hiển th?ph?OASIS đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
Standard Features
?Full-color 7?(800 x 480 pixel) interface
?Replicates information displayed at the FACP
?Automatic display brightness adjustment
?Internal buzzer
?Connects via control panel network terminals
?Low current, 24V DC powered
?Configurable functionality
?Enable key-switch
?Sheet steel enclosure
?Surface or semi-flush enclosure options available

Technical Specifications

Supply Voltage Range

21-30V DC

Quiescent Current
during Power Failure

216mA typical (buzzer off @ 24V DC)
246mA typical (buzzer on @ 24V DC)
341mA max (buzzer on @ 21V DC)

Maximum Number of
Units on a Network

31 Annunciators

Size

9.25?x 6.7?x 2.2?(235 mm x 170 mm x 55 mm)

Display

Full color 800 x 480 LCD with resistive touch screen
and automatic back-light dimming

Construction

18 SWG, 1.2 mm mild sheet steel

Cable Entry

2 x 20 mm knockouts on top & bottom
4 x 20 mm and 2 x 28 mm knockouts in back

Vision Annunciator
Electronics Only

S787

Finish

Epoxy powder coated

Color

Enclosure
Red (RAL3002)
Gray (BS 00 A 05)
Black (RAL9005)
Fascia
Signal White (RAL9003)

Optional Semi-Flush
Mounting Collar Kit

KM1098RD – Red
KM1098GY – Gray
KM1098BS – Black

Weight

4.4 lbs (2 kg) maximum

IP Rating

IP30

The post B?hiển th?ph?OASIS first appeared on Công ty TNHH Mela.

Bài viết B?hiển th?ph?OASIS đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/bo-hien-thi-phu-oasis/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-ltitude-2-16-loops/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-bao-chay-dia-chi-ltitude-2-16-loops //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-ltitude-2-16-loops/#respond Thu, 04 Jun 2020 03:40:34 +0000 //demo1.x-zel.com/?post_type=product&p=349 The all new L@titude product range of fire alarm control equipment combines the very latest hardware and software to produce a control and indication system, which is powerful and sophisticated, yet simple to use and understand. The flexibility of the L@titude platform is such that it can be re-configured to realize many other control and indication applications, with direct integration into intelligent buildings.

⇓Tải v?catalogue Trung tâm báo cháy địa ch?L@titude 2 - 16 loops

The post Trung tâm báo cháy địa ch?L@titude 2 ?16 loops first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?L@titude 2 – 16 loops đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

L@titude
Analog Addressable Fire Alarm Control Panels    


Standard Features
?UL Listed (Tenth Edition) and FM Approved
?2 to 8 loop or 2 to 16 loop versions
?400mA loop current
?4 programmable NACs; Class B or 2 Class
A with internal synchronization
?5.25 A or 10.25 A power supply options
?3 programmable inputs and 5
programmable relay outputs
?7 inch, full-color resistive touch screen
with intuitive user interface
?Up to 24 programmable soft “function keys?br />?Up to 64 user login accounts
?Hard-wired fire and trouble routing inputs and outputs
?Modular and expandable electronics
?400 subaddress points per loop (800 per loop module)
?Option to “invert?inputs and outputs
?5000 programmable cause and effects;
over 50,000 inputs and outputs
?Can be networked with programmable functionality
?Programming via USB port to PC or memory stick

The post Trung tâm báo cháy địa ch?L@titude 2 ?16 loops first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?L@titude 2 – 16 loops đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-ltitude-2-16-loops/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-elite-h-2-4-loops/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-bao-chay-dia-chi-elite-h-2-4-loops //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-elite-h-2-4-loops/#respond Thu, 04 Jun 2020 03:30:48 +0000 //demo1.x-zel.com/?post_type=product&p=373 The VF1420 and VF1440 analog addressable FACP with networked releasing, supports 2 or 4 SLC loops
for a total of 500 primary points and up to 800 points using subpoints. SLC loop communications uses
standard twisted pair cabling, shielded cable is not necessary.
The panel may be configured with various communication cards; Communications options support remote programming, central station monitoring, Virtual Panel, and networking.
The Panel can be configured as a stand-alone panel with just a few devices for a small building; it can also
operate as the building system and can be part of a network with a total of 64 nodes serving a multiple building campus or a very large facility.
Autolearn capability provides a convenient method to troubleshoot new installations before final programming is loaded.

⇓Tải xuống Catalogue Thiết b?báo cháy địa ch?Elite-H (2-4 Loops)

The post Trung tâm báo cháy địa ch?Elite-H (2-4 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?Elite-H (2-4 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Elite-H| Analog Addressable Fire Control Panels

VF1420-10 (2 Loop)
VF1440-10 (4 Loop)



Standard Features
?UL 864 9th Edition listed
?Multi-Loop 2 Analog Addressable Loops Field upgradable to 4
?127 primary points per loop
?Powerful, network wide cause and effects (500 total)
Fully user programmable by point or zone.
?Up to 800 points per panel when using devices and sub-points
?Up to 10,000 feet wiring length on SLC loop
?64 Panels on a network
?Programmable through a PC connection
to the panel, or through keypad
?Programmable on-board relays ?5
?Supervised Powered Outputs ?3
?Programmable Notification Appliance Circuits: 4
?Power per NAC: 1.6 Amps Max
?Programmable outputs on SLC loop
?Programmable Function button on front display
?Fire Drill button on front display
?Day and night sensitivity settings (user programmable)
?Power Supply: 5.25 Amp, regulated & integrated
?LCD Display: 8×40
?Zonal Mode: Annunciation by zone w/o individual relationships
?Panel Ring Modes: Common, Zonal, Stage 2
?NAC Outputs programmable as Continuous, March, Temporal
?Program Cause and Effects AND, OR, or Any Two (Cross Zone)
?Battery size: Up to 17 Ah in standard enclosure;
up to 52 Ah with external cabinet
?Access levels: 3
?Access key switch: Yes
?Recognized for use in High Rise
?One man walk test ?Fire Test Mode
?Available with semi flush trim ring
?Available in Red or Gray

The post Trung tâm báo cháy địa ch?Elite-H (2-4 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?Elite-H (2-4 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-elite-h-2-4-loops/feed/ 0
Thiết b?báo cháy VES - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-elite-rs-1-2-loops/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-bao-chay-dia-chi-elite-rs-1-2-loops //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-elite-rs-1-2-loops/#respond Thu, 04 Jun 2020 03:20:10 +0000 //demo1.x-zel.com/?post_type=product&p=370 Elite RS is a versatile range of open protocol fire alarm control panels compatible with existing Elite fire alarm panel technology.
Available with one or two detection loops for a total of 254 primary SLC points or up to 800 points using addresses and subaddresses. Elite RS uses leading edge microprocessor based electronics to provide a flexible control system with high reliability and integrity.
Suitable for all small to medium sized fire detection systems, Elite RS control panels can be expanded and networked to become part of much larger systems if the need arises, therefore providing a future proof solution for any installation.
With its large graphical display and ergonomic button and indicator layout, the Elite RS control panel is simple and straightforward to understand for installers, commissioning engineers, and end users alike.

⇓Tải v?Catalogue Trung tâm báo cháy địa ch?Elite RS (1-2 Loops)

The post Trung tâm báo cháy địa ch?Elite RS (1-2 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?Elite RS (1-2 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Elite RS| Analog Addressable Fire Control Panels 

VF0810-10 (1 Loop)
VF0820-10 (2 Loop)

Standard Features
?One full SLC circuit expandable to two 3 programmable relays
?5.25A power supply
?Large graphic display
?Real time clock
?Compatible with eMATRIX graphics annunciator
?Powerful, network wide cause and effects (500 total)
?Fully userprogrammable by point or zone
?Can be networked with additional RS and/ or Elite control panels
?Compatible with eVIEW Annunciator
?Programmable through a PC connection to the panel
?Same look and feel as Elite range
?Stores 1000 last events in history log
?Model ranges include with or without a Dual-Line internal DACT
?Compact, stylish enclosure
?Available in Red or Gray
?2 Programmable NAC circuits with internal synchronization support

The post Trung tâm báo cháy địa ch?Elite RS (1-2 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?Elite RS (1-2 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-elite-rs-1-2-loops/feed/ 0