Module địa ch?- Công ty TNHH Mela //x-zel.com Nhà phân phối thiết b?PCCC Mon, 30 Nov 2020 02:42:41 +0000 vi hourly 1 //wordpress.org/?v=6.2.3 //x-zel.com/wp-content/uploads/2021/11/New-Melaco-fire-protection-logo-81x81.png Module địa ch?- Công ty TNHH Mela //x-zel.com 32 32 Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/bo-cai-dat-dia-chi-vf9000-00/?utm_source=rss&utm_medium=rss&utm_campaign=bo-cai-dat-dia-chi-vf9000-00 //x-zel.com/san-pham/bo-cai-dat-dia-chi-vf9000-00/#respond Wed, 03 Jun 2020 03:27:07 +0000 //demo1.x-zel.com/?post_type=product&p=512 The Hand Held Programmer is designed for use with all analog sensors and modules.

Address Setting
1. Install sensor onto programmer, ensuring that sensor protrusions align with programmer grooves.
2. Press the left gray button to switch programmer on. A battery check message will appear followed by the device’s address (Unprogrammed sensors will read address 127).
3. Set the required address by incrementing the left and right gray buttons (the display will show three red flashing dots if the address being programmed is different from the device’s current address).
4. When the desired address is present, press the blue button to store that address. The three red dots on the display will no longer be present.

?Tải xuống Catalogue VF9000

The post B?cài đặt địa ch?VF9000-00 first appeared on Công ty TNHH Mela.

Bài viết B?cài đặt địa ch?VF9000-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Handheld Programmer
VF9000-00       


Standard Features
?Compact unit
?Easy to use
?Provides address setting and reading
?Can be used on both sensors and modules
?Has the diagnostic ability to display the analog value
?Over 8000 address settings from one battery

Technical Specifications

Rated Voltage 9 VDC
Battery 9 VDC
Weight 0.34 lbs
Length 6 ¼?/span>
Color White

Display Messages

bAt On upon power up (battery check). Also on when battery is low. Low
battery good for up to 3,000 address setting operation.
E0 Attempting to set an address beyond 127
E1 Attempting to program an address with no device connected
E2 Cannot find device after power up
E3 Invalid sensor response
E4 Cannot find the device program
E5 Device read error
E6 Fail during analog value reading

The post B?cài đặt địa ch?VF9000-00 first appeared on Công ty TNHH Mela.

Bài viết B?cài đặt địa ch?VF9000-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/bo-cai-dat-dia-chi-vf9000-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-output-dieu-khien-coi-chuong-den-vf6040-00-vf-6041-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-output-dieu-khien-coi-chuong-den-vf6040-00-vf-6041-00 //x-zel.com/san-pham/module-output-dieu-khien-coi-chuong-den-vf6040-00-vf-6041-00/#respond Wed, 03 Jun 2020 03:18:37 +0000 //demo1.x-zel.com/?post_type=product&p=509 The Class A Supervised Output Modules (DCP-SOM-A and SOM-AI) have been designed to provide application flexibility and quick response to emergency conditions.
Flexibility is provided by a wide range of operating modes, including supporting multi-zone operations, and/ or functions, up to 16 different modulation patterns and multi-state programming. The operating parameters for the DCP-SOM-A and -AI are maintained by the module and do not require individual communication with the control system during emergency conditions to operate.
The control panel simply broadcasts system conditions on the Signaling Line Circuit (SLC) and the DCP-SOM-A and -AI modules do the rest based upon the custom configuration. Each DCP-SOM-A and -AI provides a single Class B or Class A circuit rated for 2.0 Amps @ 24 VDC. Each DCPSOM-A and -AI also requires a 24 VDC power source in addition to the SLC.

?Tải xuống Catalogue VF6040 | VF6041

The post Module Output điều khiển còi, chuông, đèn VF6040-00 | VF 6041-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output điều khiển còi, chuông, đèn VF6040-00 | VF 6041-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Supervised Output Modules (Class A Wiring)
VF6040-00 and VF6041-00 (with Short Circuit Isolator)       


Standard Features
?Built-in SCI circuitry (VF6041-00 only)
?Flexible application
?Quick response to emergency conditions
?Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required
?Contacts are rated 2.0 Amps @ 24VDC
?Programming is highly flexible providing 16 priority states plus zoning capability
?Programmed device output is turned off, silenced, or programmed to output the selected pattern

Technical Specifications

Supply Voltage Nominal 25.3-39 VDC
Auxiliary Supply Voltage 24 VDC
Average Current Consumption VF6040 420μA (Typical)
VF6041 220μA (Typical)
On S-SC Line Maximum 6mA (Alarm)
Current Consumption on Auxiliary Power Lines50μA (typical)
SCI on Resistance 40 ohm max (normal condition)
SCI Fault Detection Threshold 12 Volts (typical)
SCI Isolation Current (short circuit condition)10mA (typical)
Maximum Quantity per Loop 127
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation Temperature Range32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Output điều khiển còi, chuông, đèn VF6040-00 | VF 6041-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output điều khiển còi, chuông, đèn VF6040-00 | VF 6041-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-output-dieu-khien-coi-chuong-den-vf6040-00-vf-6041-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-output-dieu-khien-coi-chuong-den-vf6004-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-output-dieu-khien-coi-chuong-den-vf6004-00 //x-zel.com/san-pham/module-output-dieu-khien-coi-chuong-den-vf6004-00/#respond Wed, 03 Jun 2020 03:11:00 +0000 //demo1.x-zel.com/?post_type=product&p=506 The VES Supervised Output Module, VF6004 is designed for use on the Elite analog addressable system. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an on-board EEPROM. The module allows the panel to control and monitor for circuit integrity and output functions as defined.
The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The module has a single bi-colored LED to indicate device status. It fits into a standard 4?square or double gang electrical back box. After addressing, Supervised Output Modules are fully configurable through Loop Explorer programming software.

?Tải xuống Catalogue VF6004

The post Module Output điều khiển còi, chuông, đèn VF6004-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output điều khiển còi, chuông, đèn VF6004-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Supervised Output Module
VF6004-00      


Standard Features
?Flexible application
?Quick response to emergency conditions
?Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required
?Contacts are rated 2A @ 30VDC
?Programming is highly flexible providing 16 priority states plus zoning capability
?Program status: LED will flash red or green
?Programmed device output is turned off, silenced, or programmed to modulate pattern

Application
The Supervised Output Module, VF6004, has been designed to provide application flexibility and quick response to emergency conditions. Flexibility is provided by a wide range of operating modes, including supporting multi-zone operations, and/or functions, up to 16 different modulation patterns and multi-state programming.
The operating parameters for the VF6004 are maintained by the module and do not require individual communication with the control system during emergency conditions to operate. The control panel simply broadcasts system conditions on the Signaling Line Circuit (SLC) and the VF6004s do the rest based upon the custom configuration.


Technical Specifications

Operating Voltage 17 – 41 VDC
Average Current Consumption 220µA (Standby)
300µ
A (Alarm)
Auxiliary Supply Voltage Nominal 18 – 30 V
Current Consumption on Auxiliary Power Lines 18 – 30 V
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation Temperature Range 32ºF – 120ºF (0ºC – 49ºC)
Dimensions 4.2?W) x 4.7?H) x 1.4?D)

The post Module Output điều khiển còi, chuông, đèn VF6004-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output điều khiển còi, chuông, đèn VF6004-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-output-dieu-khien-coi-chuong-den-vf6004-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-ket-noi-dau-bao-thuong-vf6011/?utm_source=rss&utm_medium=rss&utm_campaign=module-ket-noi-dau-bao-thuong-vf6011 //x-zel.com/san-pham/module-ket-noi-dau-bao-thuong-vf6011/#respond Wed, 03 Jun 2020 03:01:28 +0000 //demo1.x-zel.com/?post_type=product&p=503 The VF6011 is designed for use on the Elite analog addressable system. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM.
The module allows the panel to interface and monitor two-wire conventional detectors. Each VF6011 transmits the status of one zone of devices (25 maximum per zone) back to the panel.
The VF6011 supervises the power supply as well as the entire zone of devices. Status conditions are reported as normal, open or alarm. All 2-wire smoke detectors must be UL listed as compatible to be interfaced with the VF6011.
The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The module has a single bi-colored LED to indicate device status. It fits into a standard 4?square or double gang electrical back box. After addressing, Conventional Zone Modules are fully configurable through Loop Explorer Programming Software.

?Tải xuống Catalogue VF6011

The post Module Kết nối đầu báo thường VF6011 first appeared on Công ty TNHH Mela.

Bài viết Module Kết nối đầu báo thường VF6011 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Conventional Zone Module
VF6011-00     


Standard Features
?Provides an address point for a zone of up to 25 conventional smoke detectors
?Blinks green when polled. Latched on red (controlled by panel) when activated
?Device address can also be programmed with a handheld programmer. Device address- ranges from 1 to 127
?Compatible with Class B (Style B) and Class A (Style D) wiring
?Auxiliary power source provides power for the zone of detectors
?Compatible with conventional VES detectors
Application
The VF6011 provides installing dealers with the ability to upgrade locations on a phased approach or monitor a zone of conventional detectors.
This capability is key to satisfying customer needs for a system upgrade over time, and allows a best case application of technology to match the upgrade with the customer’s budget.
All sensors may be monitored by the same Elite Panel during the upgrade, reducing the potential confusion of “old
and new?panel alarms.

Technical Specifications

Operating Voltage 17-41 VDC
Average Current Consumption (S, SC) 400μA (typical)
Auxiliary Supply Voltage Nominal 18.8-27.2 V
2 Wire Detector Loop Current Standby Det. Load 1mA
Data Transmission Current Temp. Range 22mA ± 20%
Alarm Threshold Level <1.5K Ohms
From Aux Supply Alarm (Short Across Det. Line) 60mA
Max. 2-Wire Conventional Det. Loop Resistance 50 Ohms (total SLC Length)
Open Circuit Threshold Level >10K ohms
End-of-Line Device 4.7K Ohms
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation Temperature Range 32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Kết nối đầu báo thường VF6011 first appeared on Công ty TNHH Mela.

Bài viết Module Kết nối đầu báo thường VF6011 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-ket-noi-dau-bao-thuong-vf6011/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00 //x-zel.com/san-pham/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00/#respond Wed, 03 Jun 2020 02:53:25 +0000 //demo1.x-zel.com/?post_type=product&p=500 The Dual Relay Modules have been designed to provide flexible and quick response to emergency conditions. The VES Series allows independent control of two form C contacts for a variety of normally open and normally closed contact applications such as fan operation, elevator recall, door closure, and auxiliary notification.
Each VES Series module provides independent control of two Form C contacts while utilizing one SLC (Signaling Line Circuit) address. The modules have a highly configurable programming algorithm that allows the user to set up groups of devices (zoning) for simultaneous operation of multiple VF6052, VF6053, VF6054, and VF6055 modules. The operating parameters are maintained by the module and do not require individual communication with the control panel during the emergency condition to operate. The control panel broadcasts the control command on the SLC loop and the VES Series modules do the rest based on their custom configuration. Since mechanically latching relays are used within the VES Series modules, a separate 24VDC power source is not required.

?Tải xuống Catalogue VF6052|VF6053|VF6054|VF6055

The post Module Output R?le điều khiển VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output R?le điều khiển VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Dual Relay Modules
VF6052-00 (Low Voltage), VF6053-00 (Low Voltage w/ Isolator),
VF6054-00 (High Voltage), VF6055-00 (High Voltage w/ Isolator)
    


Standard Features
?Provides two independently configurable Form C contacts per address
?Contacts are rated as follow:
?VF6052/ VF6053: 2A @ 30 VDC / 0.5A @ 120 VAC
?VF6054/ VF6055: 8A @ 30VDC / 4.8A @ 250 VAC
?Up to127 devices can be used on each SLC loop
?Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on when activated. (For All Models)
?Yellow LED indicates a short circuit condition (VF6053 and VF6055 only)
?Programming is highly flexible providing 16 priority states plus zoning capability
?Operates on Class A or Class B SLC loop

Technical Specifications

Supply Voltage Nominal 25.3-39 VDC
Average Current Consumption350μA (typical)
405
μA (alarm)
Contacts 2 Independently Controlled Form C
VF6052/VF6053
2A @ 30 VDC/ 0.5A @ 120 VAC
VF6054/VF6055
8A @ 30 VDC/ 4.8A @ 250 VAC
SCI on Resistance 40 ohm max (normal condition)
SCI Fault Detection Threshold 12 Volts (typical)
SCI Isolation Current (Short Circuit Condition)10 mA (typical)
Maximum Quantity per Loop 127
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Output R?le điều khiển VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output R?le điều khiển VF6052-00 | VF6053-00 | VF6054-00 | VF6055-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-output-ro-le-dieu-khien-vf6052-00-vf6053-00-vf6054-00-vf6055-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-input-giam-sat-doi-2-ngo-vao-vf6007-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-input-giam-sat-doi-2-ngo-vao-vf6007-00 //x-zel.com/san-pham/module-input-giam-sat-doi-2-ngo-vao-vf6007-00/#respond Wed, 03 Jun 2020 02:45:05 +0000 //demo1.x-zel.com/?post_type=product&p=497 The VES Dual Monitor Module (VF6007) is designed for use on the Elite analog addressable system. It provides two independent contact monitoring circuits while only utilizing one address on the SLC loop.
Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM. The module can be programmed to monitor normally open (NO) or normally closed (NC) contact fire alarm and supervisory devices.
The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions.
The module has a single bi-colored LED to indicate device status. It fits into a standard 4?square or double gang electrical back box.

?Tải xuống Catalogue VF6007

The post Module Input Giám sát đôi (2 ngõ vào) VF6007-00 first appeared on Công ty TNHH Mela.

Bài viết Module Input Giám sát đôi (2 ngõ vào) VF6007-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Dual Input Monitor Modules
VF6007-00    


Standard Features
?Fast, reliable contact monitoring utilizing the VES DCP (Digital Communications Protocol)
?127 devices can be used per DCP loop
?Bi-colored indicating LED provides module status
?Dual input contact monitor
?Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
?Operates on Class A or Class B SLC loop
?Accepts up to 14 AWG wire
?Mounts to 4?square gang box

Application
The VES VF6007 provides installing dealers an economical approach to monitor devices in the same proximity, such as water flow and valve supervision on the same interface device.
This capability when coupled with VES’s SIA DACT transmission provides sub-point reporting for complete annunciation and accurate reporting to responders and users.
VES’s reporting approach is superior in that the capability to accurately report dissimilar inputs, such as alarm and supervisory are present.


Technical Specifications

Operating Voltage 17-41 VDC
Average Current Consumption 600μA (Typical)
Alarm Current 30 mA
Maximum Quantity per Loop 127
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Input Giám sát đôi (2 ngõ vào) VF6007-00 first appeared on Công ty TNHH Mela.

Bài viết Module Input Giám sát đôi (2 ngõ vào) VF6007-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-input-giam-sat-doi-2-ngo-vao-vf6007-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-cach-ly-vf6003-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-cach-ly-vf6003-00 //x-zel.com/san-pham/module-cach-ly-vf6003-00/#respond Wed, 03 Jun 2020 02:31:01 +0000 //demo1.x-zel.com/?post_type=product&p=494 Class A Configuration Wiring - The VF6003 short circuit isolator should be located between any devices on the SLC loop. In the event of a short on the SLC loop, the two adjacent isolators (closest isolators to the left and right of the shorted section) will activate and their respective LED indicators will be turned on. All devices between the active short circuit isolators will be dead. This will prevent an entire loop failure. Upon removal of the short condition, the VF6003 devices will automatically restore the entire loop to the normal operating state.
Class B Configuration Wiring - The VF6003 short circuit isolator should be located between any devices on the SLC loop. In the event of a short on the SLC loop, an isolator closest to the shorted section will activate and the LED will be turned on. All the devices beyond the shorted section will be disabled. Upon removal of the short condition, the VF6003 will automatically restore the entire loop to the normal operating state. For the best performance, use class A configuration.

?Tải xuống Catalogue VF6003

The post Module cách ly VF6003-00 first appeared on Công ty TNHH Mela.

Bài viết Module cách ly VF6003-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Short Circuit Isolator
VF6003-00   


Standard Features
?Can be placed at any location on SLC loop
?Checks the line for short circuit at power up; if the line is normal, the relay
will be returned on. If a line short is detected, the relay remains open
?Indication of short circuit by a yellow LED
Application
The VES VF6003 Short Circuit Isolator provides the capability of allowing NFPA SLC
Style 7 installations

Technical Specifications

Absolute Maximum Applied
Voltage
S, SC 41 VDC
Supply Voltage Nominal S, SC 33 VDC
Normal Current Consumption 270 μA
Average Current Consumption
(Short Circuit Condition)
10 mA
Visual Indicator (Yellow Status
LED)
Normal Condition No indication
Active (Short) Condition On Steady
SLC Maximum Resistance 50 ohms
Weight 1.4 oz
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module cách ly VF6003-00 first appeared on Công ty TNHH Mela.

Bài viết Module cách ly VF6003-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-cach-ly-vf6003-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-giam-sat-vf6024-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-giam-sat-vf6024-00 //x-zel.com/san-pham/module-giam-sat-vf6024-00/#respond Wed, 03 Jun 2020 02:24:53 +0000 //demo1.x-zel.com/?post_type=product&p=491 The VF6024 Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The VF6024 contact monitoring module does not require a separate 24 VDC power source.
Each addressable contact monitoring module is programmed with its own unique Signaling Line Circuit (SLC) loop address. The device address is electrically programmable and stored in onboard EEPROM. Up to 127 devices can be placed on the DCP SLC loop. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. It can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts. If a fault condition occurs in the wiring, the module sends a trouble status signal to the fire alarm control panel. When a change of status (contact changes state) is sensed by the VF6024 it sends an interrupt to the control panel indicating that an alarm has occurred.

?Tải xuống Catalogue VF6024

The post Module giám sát VF6024-00 first appeared on Công ty TNHH Mela.

Bài viết Module giám sát VF6024-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Fast Response Contact Modules
VF6024-00  


Standard Features
?Single input contact monitor
?Fast, reliable contact monitoring utilizing the DCP (Digital Communications Protocol)
?127 devices can be used per DCP loop
?Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
?Operates on Class A or Class B SLC loop
?Accepts up to 14 AWG wire

Technical Specifications

Supply Voltage (S-SC) 25.3-39 VDC
Average Current Consumption 339 μA (typical)
358 mA (Alarm)
Programmable Input 1 Monitoring Input
EOL Device 10K Ohms Resistor
Maximum Quantity per Loop 127
Mounting 2?Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 1.75?W x 2.37?H x 0.5?D

The post Module giám sát VF6024-00 first appeared on Công ty TNHH Mela.

Bài viết Module giám sát VF6024-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-giam-sat-vf6024-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-giam-sat-vf6020-00-vf6021-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-giam-sat-vf6020-00-vf6021-00 //x-zel.com/san-pham/module-giam-sat-vf6020-00-vf6021-00/#respond Wed, 03 Jun 2020 02:18:31 +0000 //demo1.x-zel.com/?post_type=product&p=488 The VES VF6020 and VF6021 Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact alarm initiating devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. Two different mounting configurations are provided to meet a wide range of applications. The VF6020 and VF6021 contact monitoring module does not require a separate 24 VDC power source.
Each addressable contact monitoring module is programmed with its own unique Signaling Line Circuit (SLC) loop address. The device address is electrically programmable and stored on onboard EEPROM. Up to 127 devices can be placed on the DCP SLC loop. The module supervises the wiring to the contact with an End Of Line (EOL) resistor in Class B mode. It can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts. If a fault condition occurs in the wiring, the module sends a trouble status signal to the fire alarm control panel. When a change of status (contact changes state) is sensed by the VF6020 and VF6021, it sends an interrupt to the Fire Alarm Control Panel indicating that an alarm has occurred. VF6021-00 version has builtin integrated SCI circuitry. In the event of a short on the S-SC line, the SCI circuit will activate and its yellow LED indicator will be turned on steady and the module will report the short circuit condition to the Fire Control Panel.

?Tải xuống Catalogue VF6020|vf6021

The post Module giám sát VF6020-00 | VF6021-00 first appeared on Công ty TNHH Mela.

Bài viết Module giám sát VF6020-00 | VF6021-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Fast Response Contact Modules
(Class A Wiring)
VF6020-00 and VF6021-00 (with Short Circuit Isolator)


Standard Features
?Single input contact monitor
?Fast, reliable contact monitoring utilizing the DCP (Digital Communications Protocol)
?Two different mounting configurations
?127 devices can be used per DCP loop
?Bi-colored indicating LED provides module status (Both Models)
?Yellow LED indicates a short circuit condition (VF6021-00 only)
?Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts in Class B
?Operates on Class A or Class B SLC loop
?Accepts up to 14 AWG wire

Technical Specifications

Supply Voltage Nominal 25.3-39 VDC
Average Current Consumption 630 μA (typical), 6.3 mA (Alarm)
SCI on Resistance 40 ohm Max (normal condition)
SCI Fault Detection Threshold 12 Volts (typical)
SCI Isolation Current (Short Circuit Condition) 10 mA (typical)
Maximum Quantity per Loop 127
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation Temperature Range 32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module giám sát VF6020-00 | VF6021-00 first appeared on Công ty TNHH Mela.

Bài viết Module giám sát VF6020-00 | VF6021-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-giam-sat-vf6020-00-vf6021-00/feed/ 0
Module địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/module-giam-sat-vf6013-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-giam-sat-vf6013-00 //x-zel.com/san-pham/module-giam-sat-vf6013-00/#respond Wed, 03 Jun 2020 02:12:37 +0000 //demo1.x-zel.com/?post_type=product&p=484 The Fast Response Contact Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The contact monitoring module does not require a separate 24 VDC power source.
Each addressable contact monitoring module is programmed with its own unique Signaling Line Circuit (SLC) loop address. The device address is electrically programmable and stored in on-board EEPROM. Up to 127 devices can be placed on the DCP SLC loop. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. It can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts. If a fault condition occurs in the wiring, the module sends a trouble status signal to the fire alarm control panel. When a change of status (contact changes state) is sensed by the module, it sends an interrupt to the control panel indicating that an alarm has occurred.

?Tải xuống Catalogue VF6013

The post Module giám sát VF6013-00 first appeared on Công ty TNHH Mela.

Bài viết Module giám sát VF6013-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Fast Response Contact Module
VF6013-00    


Standard Features
?Fast, reliable contact monitoring utilizing the VES DCP (Digital Communications
Protocol)
?127 devices can be used per DCP loop
?Single input contact monitor
?Can be programmed to monitor Normally Open (NO) or Normally closed
(NC) contacts
?Operates on Class A or Class B SLC loop

Technical Specifications

Supply Voltage (S-SC) 25.3 – 39 VDC
Average Current Consumption 550µA (Standby)
660µ
A (Alarm)
Programmable Input Monitoring Inputs
EOL Device 10K Ohms Resistor
Maximum Quantity per Loop 127
Maximum Humidity up to 90%, non-condensing
Operating Temperature 32ºF – 120ºF (0ºC – 49ºC)
Mounting Single gang electrical box
Dimensions 3.0?W) x 1.9?H) x 0.5?D)