Đầu báo cháy địa ch?- Công ty TNHH Mela //x-zel.com Nhà phân phối thiết b?PCCC Mon, 30 Nov 2020 02:44:24 +0000 vi hourly 1 //wordpress.org/?v=6.2.3 //x-zel.com/wp-content/uploads/2021/11/New-Melaco-fire-protection-logo-81x81.png Đầu báo cháy địa ch?- Công ty TNHH Mela //x-zel.com 32 32 Đầu báo cháy địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-khoi-ong-gio-vf5013-vf5014/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-khoi-ong-gio-vf5013-vf5014 //x-zel.com/san-pham/dau-bao-khoi-ong-gio-vf5013-vf5014/#respond Tue, 02 Jun 2020 04:56:25 +0000 //demo1.x-zel.com/?post_type=product&p=395 The VF5013 and VF5014 are designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke sensors.

?Tải xuống Catalogue VF5013|VF5014

The post Đầu báo khói ống gió VF5013 | VF5014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói ống gió VF5013 | VF5014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Analog Duct Sensors
VF5013-00 and VF5014-00 (with relays)   


Standard Features
?Detects and limits the spread of smoke
throughout building HVAC ducts
?Compatible with building automation
and fire alarm systems
?Installs quickly and easily
?No screens or filters to clean
?Rugged gray steel back box with clear cover
?Accessories – Remote LED alarm indication capability
?Meets UL 268A Requirements

The post Đầu báo khói ống gió VF5013 | VF5014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói ống gió VF5013 | VF5014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-khoi-ong-gio-vf5013-vf5014/feed/ 0
Đầu báo cháy địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-nhiet-dia-chi-vf2010/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-nhiet-dia-chi-vf2010 //x-zel.com/san-pham/dau-bao-nhiet-dia-chi-vf2010/#respond Tue, 02 Jun 2020 04:48:32 +0000 //demo1.x-zel.com/?post_type=product&p=391 The VF2010 incorporates a highly linear thermistor circuit. The specially designed cover protects the thermistor while allowing maximum air flow. The thermistor circuit produces a voltage proportional to the temperature; this information is transmitted to the control panel as a digital value. When the ambient temperature exceeds a preprogrammed threshold (fixed temp or rate of rise), the sensor transmits an interrupt to the control panel indicating a fire alarm. The fire alarm control panel can adjust the sensor’s fixed temperature threshold for different installation requirements.
Up to 127 devices may be installed on each SLC loop. The sensor address may be set by a hand-held programming unit. The sensor mounts to an electronics-free base and incorporates a locking mechanism for security. The base provides mounting slots, terminals for field wiring and a third terminal for a remote indicator/ LED. The sensor has dual LEDs for easy viewing of the sensor status.

?Tải Xuống Catalogue VF2010

The post Đầu báo nhiệt địa ch?VF2010 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo nhiệt địa ch?VF2010 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Fixed Temp / Rate of Rise Heat Sensor
VF7010-00  


Standard Features
?Low Profile – Only 2.0?high, including base
?Simple and reliable device addressing method
?Uses the noise immune Digital Communication Protocol
(DCP), which utilizes interrupts for fast response to fires
?Rate of Rise temperature threshold = 15°F/Min (determined by panel)
?Adjustable threshold temperature = 135°F – 190°F (determined by panel)
NOTE Bases are not included with detectors, please order separately

Technical Specifications

Operating Voltage

24 – 41 VDC

Standby Current

350μA

Alarm Current

500μA

Transmission Method

DCP—Digital Communication Protocol

Maximum Humidity

up to 95% non-condensing

UL Temperature Range

135º F to 190º F

Operating Temperature Range

14º F to 122º F

Rate of Rise

15º F Minimum

UL Maximum Spacing

70 feet

Color / Case Material

Bone / ABS Blend

Weight

3.2 oz, (4.9 oz with 4?base)


Ordering Codes

VF2014-00

Multi-Criteria Sensor

VF7001-00

4?Mounting Base

VF7002-00

6?Mounting Base

VF7005-00

6?Low Frequency Sounder Base

The post Đầu báo nhiệt địa ch?VF2010 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo nhiệt địa ch?VF2010 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-nhiet-dia-chi-vf2010/feed/ 0
Đầu báo cháy địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-khoi-nhiet-co-ket-hop-dia-chi-vf2014/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-khoi-nhiet-co-ket-hop-dia-chi-vf2014 //x-zel.com/san-pham/dau-bao-khoi-nhiet-co-ket-hop-dia-chi-vf2014/#respond Tue, 02 Jun 2020 04:39:45 +0000 //demo1.x-zel.com/?post_type=product&p=388 The VF2014 smoke detection chamber consists of a light-emitting diode (LED) and photodiode arrangement. The chamber is designed such that light emitted by the LED cannot normally reach the photodiode. In the event of fire, particles of smoke enter the chamber and scatter the light. As the smoke level increases, the scattering effect increases, causing more light to hit the photodiode. The chamber contains a unique design which allows smoke to enter the chamber while preventing external light from affecting the photodiode. The photodiode input level is sampled to sense smoke density. When the smoke density exceeds a pre-set threshold the sensor transmits an interrupt to the fire control panel indicating a fire condition.
The fire alarm control panel can adjust the sensor threshold to compensate for contamination.
The VF2014 heat portion incorporates a highly linear thermistor circuit, with two thermistors mounted externally. The specially designed cover protects the thermistor while allowing maximum air flow. The thermistor circuit produces a voltage proportional to temperature which is scaled, and transmitted as a digitally encoded value to the control panel. When the ambient temperature exceeds a preprogrammed threshold (fixed temperature), the sensor transmits an interrupt to the control panel indicating a fire alarm. The fire alarm control panel can adjust the sensor threshold for different requirements.
The VF2014 CO sensing cell serves a dual purpose of supplementing smoke detection in combination with the photodiode arrangement and monitoring colorless, odorless, and deadly CO levels. When the carbon monoxide exceeds the poisonous levels, the sensor transmits an interrupt to the control panel indicating a CO alarm.

?Tải xuống Catalogue VF2014

The post Đầu báo khói + nhiệt + CO kết hợp địa ch?VF2014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói + nhiệt + CO kết hợp địa ch?VF2014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Multi-Criteria Sensor – CO, COHb, Smoke, Heat
VF2014-00


Standard Features
?16 Programmable Modes of Operation, based upon 9 different
detection factors allow extreme application flexibility
?Compatible with VF7005 Low Frequency Sounder
base to provide a prioritized Temporal 3 Signal in
case of Fire or Temporal 4 Signal in case of CO
?Simple and reliable device addressing method
?Automatic compensation for sensor contamination
?Built-in fire test feature
?Uses the noise immune Digital Communication Protocol
(DCP), which utilizes interrupts for fast response to fires
?Dual programmable LEDs provide visual alarm / power indications
?Non-directional smoke chamber
?Pre-Alarm Function
?10 year life span on CO sensor

Ordering Codes

VF2014-00

Multi-Criteria Sensor

VF7001-00

4?Mounting Base

VF7002-00

6?Mounting Base

VF7005-00

6?Low Frequency Sounder Base

The post Đầu báo khói + nhiệt + CO kết hợp địa ch?VF2014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói + nhiệt + CO kết hợp địa ch?VF2014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-khoi-nhiet-co-ket-hop-dia-chi-vf2014/feed/ 0
Đầu báo cháy địa ch?- Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-khoi-dia-chi-vf2011-00/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-khoi-dia-chi-vf2011-00 //x-zel.com/san-pham/dau-bao-khoi-dia-chi-vf2011-00/#respond Tue, 02 Jun 2020 04:18:53 +0000 //demo1.x-zel.com/?post_type=product&p=382 The detection chamber consists of a light-emitting diode (LED) and photodiode arrangement. The chamber is
designed such that light emitted by the LED cannot normally reach the photodiode. In the event of fire, particles
of smoke enter the chamber and scatter the light. As the smoke level increases, the scattering effect increases, causing more light to hit the photodiode. The chamber contains a unique baffle design which allows smoke to enter the chamber while preventing external light from affecting the photodiode. The photodiode input level is sampled to sense smoke density.
When the smoke density exceeds a preset threshold the sensor transmits an interrupt to the fire control panel
indicating a fire condition. The fire alarm control panel can adjust the sensor threshold to compensate for
contamination.
Up to 127 devices are permitted on each SLC loop. A sensor address is set by a hand-held programming unit.
The sensor mounts to an electronics-free base and incorporates a locking mechanism for secure installation. The base provides mounting slots, terminals for field wiring and a third contact for a remote indicator/LED. The sensor incorporates dual LEDs for easy viewing of sensor status.

⇓TẢI XUỐNG CATALOGUEỊA VF2011

The post Đầu Báo Khói Địa Ch?VF2011-00 first appeared on Công ty TNHH Mela.

Bài viết Đầu Báo Khói Địa Ch?VF2011-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Photoelectric Smoke Sensor
VF2011-00


Standard Features
?Low Profile – Only 2?high, including base
?Simple and reliable device addressing
?Automatic compensation for sensor contamination
?Built-in fire test feature
?Uses the noise-immune Digital Communication Protocol
(DCP), which utilizes interrupts for fast response to fires
?Two built-in power/alarm LEDs
?Programmable non-polling LEDs
?Non-directional smoke chamber
?Vandal resistant security locking feature
?Removable smoke labyrinth for cleaning or replacement
NOTE Bases are not included with detectors, please order separately

Ordering Codes

VF2011-00

Photoelectric Smoke Detector

VF7001-00

4?Mounting Base

VF7002-00

6?Mounting Base

VF7008-00

6?Sounder Base

VF7005-00

6?Low Frequency Sounder Base

The post Đầu Báo Khói Địa Ch?VF2011-00 first appeared on Công ty TNHH Mela.

Bài viết Đầu Báo Khói Địa Ch?VF2011-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-khoi-dia-chi-vf2011-00/feed/ 0