Trung tâm báo cháy thường - Công ty TNHH Mela //x-zel.com Nhà phân phối thiết b?PCCC Mon, 09 Nov 2020 02:49:47 +0000 vi hourly 1 //wordpress.org/?v=6.2.3 //x-zel.com/wp-content/uploads/2021/11/New-Melaco-fire-protection-logo-81x81.png Trung tâm báo cháy thường - Công ty TNHH Mela //x-zel.com 32 32 Trung tâm báo cháy thường - Công ty TNHH Mela //x-zel.com/san-pham/cong-tac-khan-bao-chay-as3036-as3037-as3038-as3039-as3045/?utm_source=rss&utm_medium=rss&utm_campaign=cong-tac-khan-bao-chay-as3036-as3037-as3038-as3039-as3045 //x-zel.com/san-pham/cong-tac-khan-bao-chay-as3036-as3037-as3038-as3039-as3045/#respond Sat, 07 Nov 2020 04:32:41 +0000 //x-zel.com/?post_type=product&p=1644 Conventional Manual Pull Stations available in a number of configurations supporting Fire Alarm & Fire Suppression System.
Each model is constructed of a solid die cast housing and comes in glossy red. The back switch plate is plated steel. The electrical switch is rated for 10 Amps @ 120 VDC normally open contact rating. Most models are connected via terminal block connections (see ordering codes on second page)
?Tải xuống Catalogue

The post Công tắc khẩn báo cháy AS3045 | AS3046 | AS3048 | AS3049 | AS3051 first appeared on Công ty TNHH Mela.

Bài viết Công tắc khẩn báo cháy AS3045 | AS3046 | AS3048 | AS3049 | AS3051 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Conventional Devices
Manual Non-Coded Pull Station for Fire & Releasing Applications


Standard Features
?Single or Dual Action
?Enclosed switch with glass rod (included)
?10 Amps @ 120 VAC Snap Action Switch
?Made in USA


Ordering Codes

Part numberDescription
AS3045-10Conventional Pull Station for Fire Suppression Release – Red SPST
AS3045-10Conventional Pull Station for Fire Suppression Release – Red DPST
AS3045-50
Conventional Pull Station for Fire Suppression Release – Yellow SPST
AS3045-56
Conventional Pull Station for Fire Suppression Release – Yellow DPST
AS3046-10Conventional Pull Station, Single Action, Red, Hex Key SPST
AS3046-16Conventional Pull Station, Single Action, Red, Hex Key DPST
AS3048-10Conventional Pull Station, Single Action, Red, Cat 30 Key SPST
AS3048-16Conventional Pull Station, Single Action, Red, Cat 30 Key DPST
AS3049-10Conventional Pull Station, Dual Action, Red, Hex Key SPST
AS3049-16Conventional Pull Station, Dual Action, Red, Hex Key DPST
AS3051-10Conventional Pull Station, Dual Action, Red, Cat 30 Key SPST
AS3051-16Conventional Pull Station, Dual Action, Red, Cat 30 Key DPST
AS3052-10Conventional Pull Station, Single Action,Weatherproof, Red, Hex Key SPST, Pig Tails
AS3053-10Conventional Pull Station, Single Action,Weatherproof, Red, Cat 30 Key, SPST
AS3053-16Conventional Pull Station, Single Action,Weatherproof, Red, Cat 30 Key, DPST
AS3054-16Conventional Pull Station, Single Action,Explosion Proof, Red, Hex Key, DPST


Technical Specifications

Contact Rating10A @ 120 VAC
Operating Temperature-30°F (-35 °C) ~ 150°F (66°C)

The post Công tắc khẩn báo cháy AS3045 | AS3046 | AS3048 | AS3049 | AS3051 first appeared on Công ty TNHH Mela.

Bài viết Công tắc khẩn báo cháy AS3045 | AS3046 | AS3048 | AS3049 | AS3051 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/cong-tac-khan-bao-chay-as3036-as3037-as3038-as3039-as3045/feed/ 0
Trung tâm báo cháy thường - Công ty TNHH Mela //x-zel.com/san-pham/hien-thi-phu-supreme-cp-2-4-8-vung/?utm_source=rss&utm_medium=rss&utm_campaign=hien-thi-phu-supreme-cp-2-4-8-vung //x-zel.com/san-pham/hien-thi-phu-supreme-cp-2-4-8-vung/#respond Sat, 07 Nov 2020 04:32:34 +0000 //x-zel.com/?post_type=product&p=1643 The Supreme CP Annunciator provides remote status indications of the Supreme CP Fire Control Panel for fire, trouble and supervisory conditions. Status indications of the annunciator are reported for 2, 4, or 8 zones. Zone LED indicators and Status LED indicators are synchronized to light at identical rates.
The Supreme CP Annunciator includes an internal sounder and an automatic control for adjusting the lamp intensity of the Power and Trouble LEDs on the fascia of the unit.
The annunciator provides connections for 24 VDC power and RS 485 communication. The RS 485 Bus supports maximum of 7 Supreme-CP Annunciators. The Supreme CP Annunciator includes a dip switch for addressing and an End Of Line Resistor (EOLR). LEDs are included inside the annunciator for monitoring heart beat, error, transmit and receive conditions. The fascia and backbox of the Supreme CP Annunciator is provided in colors of gray or red. The user can write specific zone description on the labels to the right of the zone LEDs.
?Tải xuống Catalogue

The post Hiển th?Ph?Supreme CP 2/4/8 vùng first appeared on Công ty TNHH Mela.

Bài viết Hiển th?Ph?Supreme CP 2/4/8 vùng đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Supreme CP Annunciator


Standard Features
?UL 864 Approved
?Red or Gray
?Available for 2, 4, or 8 zone models
?Fire, Trouble and Supervisory annunciation
?Internal Buzzer
?Internal Trouble diagnosis indicators
?Easy access to terminals
?Four wire connection (data and power)
?Supervised data connection
?Up to 7 annunciators per systems
?Compatible with flush mount collar (AS1821-X0)


Ordering Codes

AS1885-12 2 Zone Panel – Red
AS1885-42 2 Zone Panel – Gray
AS1885-14 4 Zone Panel – Red
AS1885-44 4 Zone Panel – Gray
AS1885-18 8 Zone Panel – Red
AS1885-48 8 Zone Panel – Gray

Technical Specifications

Size 7 1/3”W x 5 1/5”H x 2 1/5”D
Construction 18AWG mild steel
Finish Epoxy powder coated
Color Red (optional gray)
Weight 2 lbs
Input Voltage 24 VDC
Alarm Current 40 mA max @ 24 VDC
Standby Current 14 mA max @ 24 VDC
Maximum Number of Units Maximum of 7 Annunciators on the AUX 24V output and the RS-485 Serial Bus
Connector Terminals 14-24 AWG
RS-485 Serial Bus RS485 two-wire
Maximum distance from control panel – 3900 feet (1200 meters)
Belden 9271 cable
Operating Temperature 32º F to 120º F
Operating Humidity up to 93%, non-condensing

The post Hiển th?Ph?Supreme CP 2/4/8 vùng first appeared on Công ty TNHH Mela.

Bài viết Hiển th?Ph?Supreme CP 2/4/8 vùng đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/hien-thi-phu-supreme-cp-2-4-8-vung/feed/ 0
Trung tâm báo cháy thường - Công ty TNHH Mela //x-zel.com/san-pham/thiet-bi-bao-chay-supreme-cp-2-4-8-vung/?utm_source=rss&utm_medium=rss&utm_campaign=thiet-bi-bao-chay-supreme-cp-2-4-8-vung //x-zel.com/san-pham/thiet-bi-bao-chay-supreme-cp-2-4-8-vung/#respond Sat, 07 Nov 2020 04:32:30 +0000 //x-zel.com/?post_type=product&p=1642 The Supreme CP range of conventional fire control panels with optional built in communicator are available with 2, 4, or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method.
The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive gray color. A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed. Single board construction which allows easy removal of all electronic parts and ample provision of cable entry knockouts simplify installation.
4 Amp notification appliance power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances. The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.
?Tải xuống Catalogue

The post Thiết b?báo cháy Supreme CP 2/4/8 Vùng first appeared on Công ty TNHH Mela.

Bài viết Thiết b?báo cháy Supreme CP 2/4/8 Vùng đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Supreme CP
Conventional Fire Control Panels


Standard Features
?UL864 approved
?Two, four, or eight initiating circuits
?Initiating circuits individually configurable as fire or supervisory
?Two 2.5A Notification Appliance Circuits
?4.0 Amps total NAC power available
?Selectable NAC sync protocols
?5 Amp power supply
?Alarm verification selectable by zone
?Resettable AUX power output rated at 0.3A
?AUX power configurable to power off and on
?Fire condition
?Fire, Trouble and Supervisory relays
?Single person walk test function
?Many advanced configuration options
?24 hour standby with 7Ah batteries
?Maximum battery size 12Ah
?Optional DACT (SIA or Contact ID allowing user definable reporting codes)

Ordering Codes

AS1842-10/11 2 Zone Panel – Red 120V / 240V
AS1842-40/41 2 Zone Panel – Gray 120V / 240V
AS1844-10/11 4 Zone Panel – Red 120V / 240V
AS1844-40/41 4 Zone Panel – Gray 120V / 240V
AS1848-10/11 8 Zone Panel – Red 120V / 240V
AS1848-40/41 8 Zone Panel – Gray 120V / 240V
AS1852-10/11 2 Zone Panel with Dialer – Red 120V / 240V
AS1852-40/41 2 Zone Panel with Dialer – Gray 120V / 240V
AS1854-10/11 4 Zone Panel with Dialer – Red 120V / 240V
AS1854-40/41 4 Zone Panel with Dialer – Gray 120V / 240V
AS1858-10/11 8 Zone Panel with Dialer – Red 120V / 240V
AS1858-40/41 8 Zone Panel with Dialer – Gray 120V / 240V
AS1850-00 8 reporting zone DACT
AS1841-00 DACT Configuration Software


Technical Specifications

Size 14.5”W x 12.2”H x 4.25”D
Construction 18AWG mild steel
Finish Epoxy powder coated
Color Red (optional gray)
Supply Voltage 120V AC or 240V AC
AC Supply Fuse 5 Amp 250V 20mm
Power Supply DC Rating 24V 5 Amps
Maximum Battery Size 12Ah 12V (2 per panel)
Trouble Contact Rating 30V DC 1 Amp
Supervisory Contact Rating 30V DC 1 Amp
Fire Contact Rating 30V DC 1 Amp
NAC Rating 2.5A per circuit 4A Total
Detection Zone Current 1.6mA
Detection Zone EOL Resistor 6k8 5%
NAC EOL Resistor 10k 5%
Cable Capacity 14 AWG
Operating Temperature 23º F to 122º F
Operating Humidity up to 95%, non-condensing

The post Thiết b?báo cháy Supreme CP 2/4/8 Vùng first appeared on Công ty TNHH Mela.

Bài viết Thiết b?báo cháy Supreme CP 2/4/8 Vùng đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/thiet-bi-bao-chay-supreme-cp-2-4-8-vung/feed/ 0