Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com Nhà phân phối thiết b?PCCC Mon, 30 Nov 2020 02:13:05 +0000 vi hourly 1 //wordpress.org/?v=6.2.3 //x-zel.com/wp-content/uploads/2021/11/New-Melaco-fire-protection-logo-81x81.png Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com 32 32 Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/bo-cai-dat-dia-chi-as9000-00/?utm_source=rss&utm_medium=rss&utm_campaign=bo-cai-dat-dia-chi-as9000-00 //x-zel.com/san-pham/bo-cai-dat-dia-chi-as9000-00/#respond Mon, 09 Nov 2020 02:09:44 +0000 //x-zel.com/?post_type=product&p=1648 The Hand Held Programmer is designed for use with all analog sensors and modules.

Address Setting
1. Install sensor onto programmer, ensuring that sensor protrusions align with programmer grooves.
2. Press the left gray button to switch programmer on. A battery check message will appear followed by the device’s address (Unprogrammed sensors will read address 127).
3. Set the required address by incrementing the left and right gray buttons (the display will show three red flashing dots if the address being programmed is different from the device’s current address).
4. When the desired address is present, press the blue button to store that address. The three red dots on the display will no longer be present.
?Tải xuống Catalogue

The post B?cài đặt địa ch?AS9000-00 first appeared on Công ty TNHH Mela.

Bài viết B?cài đặt địa ch?AS9000-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Handheld Programmer
AS9000-00       


Standard Features
?Compact unit
?Easy to use
?Provides address setting and reading
?Can be used on both sensors and modules
?Has the diagnostic ability to display the analog value
?Over 8000 address settings from one battery

Technical Specifications

Rated Voltage 9 VDC
Battery 9 VDC
Weight 0.34 lbs
Length 6 ¼?/span>
Color White

Display Messages

bAt On upon power up (battery check). Also on when battery is low. Low
battery good for up to 3,000 address setting operation.
E0 Attempting to set an address beyond 127
E1 Attempting to program an address with no device connected
E2 Cannot find device after power up
E3 Invalid sensor response
E4 Cannot find the device program
E5 Device read error
E6 Fail during analog value reading

The post B?cài đặt địa ch?AS9000-00 first appeared on Công ty TNHH Mela.

Bài viết B?cài đặt địa ch?AS9000-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/bo-cai-dat-dia-chi-as9000-00/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-oasis-2-16-loops/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-bao-chay-dia-chi-oasis-2-16-loops //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-oasis-2-16-loops/#respond Sat, 07 Nov 2020 04:01:03 +0000 //x-zel.com/?post_type=product&p=1622 The all new OASIS product range of fire alarm control equipment combines the very latest hardware and software to produce a control and indication system, which is powerful and sophisticated, yet simple to use and understand. The flexibility of the OASIS platform is such that it can be re-configured to realize many other control and indication applications, with direct integration into intelligent buildings.
?Tải xuống Catalogue

The post Trung tâm báo cháy địa ch?OASIS 2 ?16 loops first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?OASIS 2 – 16 loops đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

OASIS
Analog Addressable Fire Alarm Control Panels    


Standard Features
?UL Listed (Tenth Edition) 
?2 to 8 loop or 2 to 16 loop versions
?400mA loop current
?4 programmable NACs; Class B or 2 Class
A with internal synchronization
?5.25 A or 10.25 A power supply options
?3 programmable inputs and 5
programmable relay outputs
?7 inch, full-color resistive touch screen
with intuitive user interface
?Up to 24 programmable soft “function keys?br />?Up to 64 user login accounts
?Hard-wired fire and trouble routing inputs and outputs
?Modular and expandable electronics
?400 subaddress points per loop (800 per loop module)
?Option to “invert?inputs and outputs
?5000 programmable cause and effects;
over 50,000 inputs and outputs
?Can be networked with programmable functionality
?Programming via USB port to PC or memory stick

The post Trung tâm báo cháy địa ch?OASIS 2 ?16 loops first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?OASIS 2 – 16 loops đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-oasis-2-16-loops/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-supreme-2-4-loops/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-bao-chay-dia-chi-supreme-2-4-loops //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-supreme-2-4-loops/#respond Sat, 07 Nov 2020 04:00:59 +0000 //x-zel.com/?post_type=product&p=1621 The AS1420 and AS1440 analog addressable FACP with networked releasing, supports 2 or 4 SLC loops
for a total of 500 primary points and up to 800 points using subpoints. SLC loop communications uses
standard twisted pair cabling, shielded cable is not necessary.
The panel may be configured with various communication cards; Communications options support remote programming, central station monitoring, Virtual Panel, and networking.
The Panel can be configured as a stand-alone panel with just a few devices for a small building; it can also
operate as the building system and can be part of a network with a total of 64 nodes serving a multiple building campus or a very large facility.
Autolearn capability provides a convenient method to troubleshoot new installations before final programming is loaded.
?Tải xuống Catalogue

The post Trung tâm báo cháy địa ch?SUPREME (2-4 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?SUPREME (2-4 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

SUPREME| Analog Addressable Fire Control Panels

AS1420-10 (2 Loop)
AS1440-10 (4 Loop)



Standard Features
?UL 864 9th Edition listed
?Multi-Loop 2 Analog Addressable Loops Field upgradable to 4
?127 primary points per loop
?Powerful, network wide cause and effects (500 total)
Fully user programmable by point or zone.
?Up to 800 points per panel when using devices and sub-points
?Up to 10,000 feet wiring length on SLC loop
?64 Panels on a network
?Programmable through a PC connection
to the panel, or through keypad
?Programmable on-board relays ?5
?Supervised Powered Outputs ?3
?Programmable Notification Appliance Circuits: 4
?Power per NAC: 1.6 Amps Max
?Programmable outputs on SLC loop
?Programmable Function button on front display
?Fire Drill button on front display
?Day and night sensitivity settings (user programmable)
?Power Supply: 5.25 Amp, regulated & integrated
?LCD Display: 8×40
?Zonal Mode: Annunciation by zone w/o individual relationships
?Panel Ring Modes: Common, Zonal, Stage 2
?NAC Outputs programmable as Continuous, March, Temporal
?Program Cause and Effects AND, OR, or Any Two (Cross Zone)
?Battery size: Up to 17 Ah in standard enclosure;
up to 52 Ah with external cabinet
?Access levels: 3
?Access key switch: Yes
?Recognized for use in High Rise
?One man walk test ?Fire Test Mode
?Available with semi flush trim ring
?Available in Red or Gray

The post Trung tâm báo cháy địa ch?SUPREME (2-4 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?SUPREME (2-4 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-supreme-2-4-loops/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-supreme-rs-1-2-loops/?utm_source=rss&utm_medium=rss&utm_campaign=trung-tam-bao-chay-dia-chi-supreme-rs-1-2-loops //x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-supreme-rs-1-2-loops/#respond Sat, 07 Nov 2020 04:00:57 +0000 //x-zel.com/?post_type=product&p=1620 Supreme RS is a versatile range of open protocol fire alarm control panels compatible with existing Supreme fire alarm panel technology.
Available with one or two detection loops for a total of 254 primary SLC points or up to 800 points using addresses and subaddresses. Supreme RS uses leading edge microprocessor based electronics to provide a flexible control system with high reliability and integrity.
Suitable for all small to medium sized fire detection systems, Supreme RS control panels can be expanded and networked to become part of much larger systems if the need arises, therefore providing a future proof solution for any installation.
With its large graphical display and ergonomic button and indicator layout, the Supreme RS control panel is simple and straightforward to understand for installers, commissioning engineers, and end users alike.

?Tải xuống Catalogue

The post Trung tâm báo cháy địa ch?Supreme RS (1-2 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?Supreme RS (1-2 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Supreme RS| Analog Addressable Fire Control Panels 

AS0810-10 (1 Loop)
AS0820-10 (2 Loop)

Standard Features
?One full SLC circuit expandable to two 3 programmable relays
?5.25A power supply
?Large graphic display
?Real time clock
?Compatible with eMATRIX graphics annunciator
?Powerful, network wide cause and effects (500 total)
?Fully userprogrammable by point or zone
?Can be networked with additional RS and/ or Supreme control panels
?Compatible with eVIEW Annunciator
?Programmable through a PC connection to the panel
?Same look and feel as Supreme range
?Stores 1000 last events in history log
?Model ranges include with or without a Dual-Line internal DACT
?Compact, stylish enclosure
?Available in Red or Gray
?2 Programmable NAC circuits with internal synchronization support

The post Trung tâm báo cháy địa ch?Supreme RS (1-2 Loops) first appeared on Công ty TNHH Mela.

Bài viết Trung tâm báo cháy địa ch?Supreme RS (1-2 Loops) đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/trung-tam-bao-chay-dia-chi-supreme-rs-1-2-loops/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/hien-thi-phu-eview-2/?utm_source=rss&utm_medium=rss&utm_campaign=hien-thi-phu-eview-2 //x-zel.com/san-pham/hien-thi-phu-eview-2/#respond Sat, 07 Nov 2020 04:00:51 +0000 //x-zel.com/?post_type=product&p=1618 Designed and manufactured to the highest standards in a quality controlled environment the eVIEW fire alarm annunciator provides a simple and convenient method of extending the controls and indications of the Elite fire alarm control panel to other locations.
The large, graphic LCD and high brightness LED indicators duplicate the indications on the Elite fire alarm control panel at up to 15 additional locations via a simple, two-wire serial data connection.
The eVIEW is powered by 24V DC (which can be via an additional 2 conductors from the control panel or local 24V DC listed supply).
eVIEW is housed in a small enclosure which is styled similarly to the Elite control panel and is ideal for installations where a large control panel would be detrimental to decor such as entrance halls.
Up to 15 eVIEW annunciators can be connected to each control panel on the Elite network making eVIEW ideal where multiple points of indication and/or control are required, such as nurses stations or shop units.

?Tải xuống Catalogue

The post Hiển Th?Ph?eVIEW first appeared on Công ty TNHH Mela.

Bài viết Hiển Th?Ph?eVIEW đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

eVIEW| Analog Addressable Serial Annunciator
AS1172-10


Standard Features
?Available in Red or Gray
?Up to 15 annunciators can be connected to each
Elite or Elite RS fire control panel
?Large liquid crystal display (240 x 64 pixels)
?High brightness LED indications
?Internal sounder
?Replicates all panel controls (Elite)
?Simple, two-wire serial connection
?Small, Elite style enclosure
?Removable electronics for easy installation
?24V DC powered
?Low power consumption
?Multi-language options
?Connection supervised by Elite fire control panel
?Recess mounting using optional AS1173 kit

The post Hiển Th?Ph?eVIEW first appeared on Công ty TNHH Mela.

Bài viết Hiển Th?Ph?eVIEW đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/hien-thi-phu-eview-2/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/module-ket-noi-dau-bao-thuong-as6011/?utm_source=rss&utm_medium=rss&utm_campaign=module-ket-noi-dau-bao-thuong-as6011 //x-zel.com/san-pham/module-ket-noi-dau-bao-thuong-as6011/#respond Sat, 07 Nov 2020 03:49:08 +0000 //x-zel.com/?post_type=product&p=1612 The AS6011 is designed for use on the Elite analog addressable system. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM.
The module allows the panel to interface and monitor two-wire conventional detectors. Each AS6011 transmits the status of one zone of devices (25 maximum per zone) back to the panel.
The AS6011 supervises the power supply as well as the entire zone of devices. Status conditions are reported as normal, open or alarm. All 2-wire smoke detectors must be UL listed as compatible to be interfaced with the AS6011.
The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The module has a single bi-colored LED to indicate device status. It fits into a standard 4?square or double gang electrical back box. After addressing, Conventional Zone Modules are fully configurable through Loop Explorer Programming Software.
?Tải xuống Catalogue

The post Module Kết nối đầu báo thường AS6011 first appeared on Công ty TNHH Mela.

Bài viết Module Kết nối đầu báo thường AS6011 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Conventional Zone Module
AS6011-00     


Standard Features
?Provides an address point for a zone of up to 25 conventional smoke detectors
?Blinks green when polled. Latched on red (controlled by panel) when activated
?Device address can also be programmed with a handheld programmer. Device address- ranges from 1 to 127
?Compatible with Class B (Style B) and Class A (Style D) wiring
?Auxiliary power source provides power for the zone of detectors
?Compatible with conventional AVENGER detectors
Application
The AS6011 provides installing dealers with the ability to upgrade locations on a phased approach or monitor a zone of conventional detectors.
This capability is key to satisfying customer needs for a system upgrade over time, and allows a best case application of technology to match the upgrade with the customer’s budget.
All sensors may be monitored by the same Elite Panel during the upgrade, reducing the potential confusion of “old
and new?panel alarms.

Technical Specifications

Operating Voltage 17-41 VDC
Average Current Consumption (S, SC) 400μA (typical)
Auxiliary Supply Voltage Nominal 18.8-27.2 V
2 Wire Detector Loop Current Standby Det. Load 1mA
Data Transmission Current Temp. Range 22mA ± 20%
Alarm Threshold Level <1.5K Ohms
From Aux Supply Alarm (Short Across Det. Line) 60mA
Max. 2-Wire Conventional Det. Loop Resistance 50 Ohms (total SLC Length)
Open Circuit Threshold Level >10K ohms
End-of-Line Device 4.7K Ohms
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation Temperature Range 32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Kết nối đầu báo thường AS6011 first appeared on Công ty TNHH Mela.

Bài viết Module Kết nối đầu báo thường AS6011 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-ket-noi-dau-bao-thuong-as6011/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/module-output-ro-le-dieu-khien-as6052-00-as6053-00-as6054-00-as6055-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-output-ro-le-dieu-khien-as6052-00-as6053-00-as6054-00-as6055-00 //x-zel.com/san-pham/module-output-ro-le-dieu-khien-as6052-00-as6053-00-as6054-00-as6055-00/#respond Sat, 07 Nov 2020 03:49:06 +0000 //x-zel.com/?post_type=product&p=1611 The Dual Relay Modules have been designed to provide flexible and quick response to emergency conditions. The AVENGER Series allows independent control of two form C contacts for a variety of normally open and normally closed contact applications such as fan operation, elevator recall, door closure, and auxiliary notification.
Each AVENGER Series module provides independent control of two Form C contacts while utilizing one SLC (Signaling Line Circuit) address. The modules have a highly configurable programming algorithm that allows the user to set up groups of devices (zoning) for simultaneous operation of multiple AS6052, AS6053, AS6054, and AS6055 modules. The operating parameters are maintained by the module and do not require individual communication with the control panel during the emergency condition to operate. The control panel broadcasts the control command on the SLC loop and the AVENGER Series modules do the rest based on their custom configuration. Since mechanically latching relays are used within the AVENGER Series modules, a separate 24VDC power source is not required.
?Tải xuống Catalogue

The post Module Output R?le điều khiển AS6052-00 | AS6053-00 | AS6054-00 | AS6055-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output R?le điều khiển AS6052-00 | AS6053-00 | AS6054-00 | AS6055-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Dual Relay Modules
AS6052-00 (Low Voltage), AS6053-00 (Low Voltage w/ Isolator),
AS6054-00 (High Voltage), AS6055-00 (High Voltage w/ Isolator)
    


Standard Features
?Provides two independently configurable Form C contacts per address
?Contacts are rated as follow:
?AS6052/ AS6053: 2A @ 30 VDC / 0.5A @ 120 VAC
?AS6054/ AS6055: 8A @ 30VDC / 4.8A @ 250 VAC
?Up to127 devices can be used on each SLC loop
?Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on when activated. (For All Models)
?Yellow LED indicates a short circuit condition (AS6053 and AS6055 only)
?Programming is highly flexible providing 16 priority states plus zoning capability
?Operates on Class A or Class B SLC loop

Technical Specifications

Supply Voltage Nominal 25.3-39 VDC
Average Current Consumption350μA (typical)
405
μA (alarm)
Contacts 2 Independently Controlled Form C
AS6052/AS6053
2A @ 30 VDC/ 0.5A @ 120 VAC
AS6054/AS6055
8A @ 30 VDC/ 4.8A @ 250 VAC
SCI on Resistance 40 ohm max (normal condition)
SCI Fault Detection Threshold 12 Volts (typical)
SCI Isolation Current (Short Circuit Condition)10 mA (typical)
Maximum Quantity per Loop 127
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Output R?le điều khiển AS6052-00 | AS6053-00 | AS6054-00 | AS6055-00 first appeared on Công ty TNHH Mela.

Bài viết Module Output R?le điều khiển AS6052-00 | AS6053-00 | AS6054-00 | AS6055-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-output-ro-le-dieu-khien-as6052-00-as6053-00-as6054-00-as6055-00/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/module-input-giam-sat-doi-2-ngo-vao-as6007-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-input-giam-sat-doi-2-ngo-vao-as6007-00 //x-zel.com/san-pham/module-input-giam-sat-doi-2-ngo-vao-as6007-00/#respond Sat, 07 Nov 2020 03:49:01 +0000 //x-zel.com/?post_type=product&p=1610 The AVENGER Dual Monitor Module (AS6007) is designed for use on the Elite analog addressable system. It provides two independent contact monitoring circuits while only utilizing one address on the SLC loop.
Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM. The module can be programmed to monitor normally open (NO) or normally closed (NC) contact fire alarm and supervisory devices.
The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions.
The module has a single bi-colored LED to indicate device status. It fits into a standard 4?square or double gang electrical back box.
?Tải xuống Catalogue

The post Module Input Giám sát đôi (2 ngõ vào) AS6007-00 first appeared on Công ty TNHH Mela.

Bài viết Module Input Giám sát đôi (2 ngõ vào) AS6007-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Dual Input Monitor Modules
AS6007-00    


Standard Features
?Fast, reliable contact monitoring utilizing the AVENGER DCP (Digital Communications Protocol)
?127 devices can be used per DCP loop
?Bi-colored indicating LED provides module status
?Dual input contact monitor
?Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
?Operates on Class A or Class B SLC loop
?Accepts up to 14 AWG wire
?Mounts to 4?square gang box

Application
The AVENGER AS6007 provides installing dealers an economical approach to monitor devices in the same proximity, such as water flow and valve supervision on the same interface device.
This capability when coupled with AVENGER’s SIA DACT transmission provides sub-point reporting for complete annunciation and accurate reporting to responders and users.
AVENGER’s reporting approach is superior in that the capability to accurately report dissimilar inputs, such as alarm and supervisory are present.


Technical Specifications

Operating Voltage 17-41 VDC
Average Current Consumption 600μA (Typical)
Alarm Current 30 mA
Maximum Quantity per Loop 127
Mounting 4?Square Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module Input Giám sát đôi (2 ngõ vào) AS6007-00 first appeared on Công ty TNHH Mela.

Bài viết Module Input Giám sát đôi (2 ngõ vào) AS6007-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-input-giam-sat-doi-2-ngo-vao-as6007-00/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/module-cach-ly-as6003-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-cach-ly-as6003-00 //x-zel.com/san-pham/module-cach-ly-as6003-00/#respond Sat, 07 Nov 2020 03:48:59 +0000 //x-zel.com/?post_type=product&p=1609 Class A Configuration Wiring - The AS6003 short circuit isolator should be located between any devices on the SLC loop. In the event of a short on the SLC loop, the two adjacent isolators (closest isolators to the left and right of the shorted section) will activate and their respective LED indicators will be turned on. All devices between the active short circuit isolators will be dead. This will prevent an entire loop failure. Upon removal of the short condition, the AS6003 devices will automatically restore the entire loop to the normal operating state.
Class B Configuration Wiring - The AS6003 short circuit isolator should be located between any devices on the SLC loop. In the event of a short on the SLC loop, an isolator closest to the shorted section will activate and the LED will be turned on. All the devices beyond the shorted section will be disabled. Upon removal of the short condition, the AS6003 will automatically restore the entire loop to the normal operating state. For the best performance, use class A configuration.

?Tải xuống Catalogue

The post Module cách ly AS6003-00 first appeared on Công ty TNHH Mela.

Bài viết Module cách ly AS6003-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Short Circuit Isolator
AS6003-00   


Standard Features
?Can be placed at any location on SLC loop
?Checks the line for short circuit at power up; if the line is normal, the relay
will be returned on. If a line short is detected, the relay remains open
?Indication of short circuit by a yellow LED
Application
The AVENGER AS6003 Short Circuit Isolator provides the capability of allowing NFPA SLC
Style 7 installations

Technical Specifications

Absolute Maximum Applied
Voltage
S, SC 41 VDC
Supply Voltage Nominal S, SC 33 VDC
Normal Current Consumption 270 μA
Average Current Consumption
(Short Circuit Condition)
10 mA
Visual Indicator (Yellow Status
LED)
Normal Condition No indication
Active (Short) Condition On Steady
SLC Maximum Resistance 50 ohms
Weight 1.4 oz
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 4.2?W x 4.7?H x 1.4?D

The post Module cách ly AS6003-00 first appeared on Công ty TNHH Mela.

Bài viết Module cách ly AS6003-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/module-cach-ly-as6003-00/feed/ 0
Báo cháy loại địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/module-giam-sat-as6024-00/?utm_source=rss&utm_medium=rss&utm_campaign=module-giam-sat-as6024-00 //x-zel.com/san-pham/module-giam-sat-as6024-00/#respond Sat, 07 Nov 2020 03:48:56 +0000 //x-zel.com/?post_type=product&p=1608 The AS6024 Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The AS6024 contact monitoring module does not require a separate 24 VDC power source.
Each addressable contact monitoring module is programmed with its own unique Signaling Line Circuit (SLC) loop address. The device address is electrically programmable and stored in onboard EEPROM. Up to 127 devices can be placed on the DCP SLC loop. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. It can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts. If a fault condition occurs in the wiring, the module sends a trouble status signal to the fire alarm control panel. When a change of status (contact changes state) is sensed by the AS6024 it sends an interrupt to the control panel indicating that an alarm has occurred.
?Tải xuống Catalogue

The post Module giám sát AS6024-00 first appeared on Công ty TNHH Mela.

Bài viết Module giám sát AS6024-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Fast Response Contact Modules
AS6024-00  


Standard Features
?Single input contact monitor
?Fast, reliable contact monitoring utilizing the DCP (Digital Communications Protocol)
?127 devices can be used per DCP loop
?Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
?Operates on Class A or Class B SLC loop
?Accepts up to 14 AWG wire

Technical Specifications

Supply Voltage (S-SC) 25.3-39 VDC
Average Current Consumption 339 μA (typical)
358 mA (Alarm)
Programmable Input 1 Monitoring Input
EOL Device 10K Ohms Resistor
Maximum Quantity per Loop 127
Mounting 2?Electrical Box
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Dimensions 1.75?W x 2.37?H x 0.5?D

The post Module giám sát AS6024-00 first appeared on Công ty TNHH Mela.