Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com Nhà phân phối thiết b?PCCC Mon, 30 Nov 2020 02:15:30 +0000 vi hourly 1 //wordpress.org/?v=6.2.3 //x-zel.com/wp-content/uploads/2021/11/New-Melaco-fire-protection-logo-81x81.png Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com 32 32 Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/de-dau-bao-kem-coi-6-as7008-00/?utm_source=rss&utm_medium=rss&utm_campaign=de-dau-bao-kem-coi-6-as7008-00 //x-zel.com/san-pham/de-dau-bao-kem-coi-6-as7008-00/#respond Sat, 07 Nov 2020 03:28:43 +0000 //x-zel.com/?post_type=product&p=1601 The AS7008 base is designed specifically for use with the VES Analog sensors, models AS2001 Ionization Smoke Sensor, AS2002, AS2005, and AS2011 Photoelectric Smoke Sensor, AS2003 and AS2010 Heat Sensorm, and AS2008 and AS2012 Multi-Criteria Sensors.
The AS7008 sounder base allows for complete compatibility for all of the VES Analog sensors.
The bases are lightweight and very thin, providing a low profile once installed. The solderless screw terminals enable quick and easy wiring connections. Addressing is automatically provided by the attached Sensor. The device is configurable through Loop Explorer Programming Software.
?Tải xuống Catalogue

The post Đ?đầu báo kèm còi 6?AS7008-00 first appeared on Công ty TNHH Mela.

Bài viết Đ?đầu báo kèm còi 6” AS7008-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

6?Analog Sounder Base
AS7008-00


Standard Features
?Programmable evacuation codes – Continuous, March, ANSI Temporal patterns
?Base learns the sensor address and assumes
an upper range address (128-254)
?Up to 127 sensors and 127 AS7008s can be used on one SLC loop
?Can be alarmed or reset by zone or by individual address
?SLC loop wire resistance = 50 ohms Max. (total SLC wire run length)
?High sound pressure level (85dB SPL at 10 feet)

Number of Bases Permitted

# Bases in
Alarm

Max. Auxiliary 24VDC Power
Wire Resistance (Total Run
Length)

10

18.3 ohm

15

12.2 ohm

20

9.1 ohm

30

6.1 ohm

50

3.6 ohm

60

3.0 ohm

75

2.4 ohm

127

1.4 ohm

NOTE SLC maximum resistance is 50 ohms.

 

The post Đ?đầu báo kèm còi 6?AS7008-00 first appeared on Công ty TNHH Mela.

Bài viết Đ?đầu báo kèm còi 6” AS7008-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/de-dau-bao-kem-coi-6-as7008-00/feed/ 0
Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/de-dau-bao-4-va-6-as7001-00-as7002-00/?utm_source=rss&utm_medium=rss&utm_campaign=de-dau-bao-4-va-6-as7001-00-as7002-00 //x-zel.com/san-pham/de-dau-bao-4-va-6-as7001-00-as7002-00/#respond Sat, 07 Nov 2020 03:19:12 +0000 //x-zel.com/?post_type=product&p=1597 The AS7001 4?bASe and AS7002 6?bASe are designed specifically for use with the VES Analog sensors, models AS2001 Ionization Smoke Sensor, AS2002, AS2005 & AS2011 Photoelectric Smoke Sensor, AS2003 & AS2010 Heat Sensor and AS2008 & AS2012 Multi-Criteria Sensors.
The AS7001 and AS7002 common mounting bASes allow for complete compatibility for all of the VES Analog sensors. The bASes are lightweight and very thin, providing a low profile once installed. The solderless screw terminals enable quick and eASy wiring connections.
?Tải xuống Catalogue

The post Đ?đầu báo 4?và 6?AS7001-00 | AS7002-00 first appeared on Công ty TNHH Mela.

Bài viết Đ?đầu báo 4″ và 6″ AS7001-00 | AS7002-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

4?and 6?Sensor Base
AS7001-00 and AS7002-00    


Standard Features
?UL Listed
?Designed for use with all analog sensors.
?Available in 4 and 6 inch models.
?Contains a security locking tab for tamper protection.

Technical Specifications

AS7001-00

4?Sensor Base

AS7002-00

6?Sensor Base

Security

Plastic tamper lock

Color and Case Material

Bone PC / ABS Blend

Compatible Sensors

AS2001, AS2002,
AS2005, AS2003,
AS2008, AS2010,
AS2011 and AS2012

The post Đ?đầu báo 4?và 6?AS7001-00 | AS7002-00 first appeared on Công ty TNHH Mela.

Bài viết Đ?đầu báo 4″ và 6″ AS7001-00 | AS7002-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/de-dau-bao-4-va-6-as7001-00-as7002-00/feed/ 0
Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/de-dau-bao-4-va-6-as7003-00-as7004-00/?utm_source=rss&utm_medium=rss&utm_campaign=de-dau-bao-4-va-6-as7003-00-as7004-00 //x-zel.com/san-pham/de-dau-bao-4-va-6-as7003-00-as7004-00/#respond Sat, 07 Nov 2020 03:19:12 +0000 //x-zel.com/?post_type=product&p=1598 The AS7003 4?isolator base and AS7004 6?isolator base are designed for use with VES analog style sensors models AS2001, AS2002, AS2005, AS2003, AS2008, AS2010, AS2011, AS2012, and AS2014.
Each isolator base is connected to an Elite Signaling Line Circuit (SLC) and provides easy replacement of sensors, without disturbing the wiring.
The isolator bases contain a simple rugged design with screw terminals for wiring connections. A common mounting base allows sensor interchange and maintains loop continuity when sensors are removed. A simple anti-tamper head Locking system is provided which is enabled by removing a small plastic tab on the back of the sensor. Once locked, the head can only be removed using a small diameter screwdriver.
?Tải xuống Catalogue

The post Đ?đầu báo 4?và 6?AS7003-00 | AS7004-00 first appeared on Công ty TNHH Mela.

Bài viết Đ?đầu báo 4″ và 6″ AS7003-00 | AS7004-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

4?and 6?Sensor Base w/ Built-In Isolator
AS7003-00 and AS7004-00   


Standard Features
?UL Listed
?Designed for use with all DCP analog sensors
?Built in LED indication upon short circuit condition
?Available in 4 and 6 inch models.
?Contains a security locking tab for tamper protection.

Technical Specifications

Operating Voltage

17-41 VDC

AS7003-00

4?Sensor Base

AS7004-00

6?Sensor Base

Current Consumption

Normal 160µA
Active 10mA

Security

Plastic tamper lock

Color and Case Material

Bone PC / ABS Blend

Compatible Sensors

AS2001, AS2002, AS2005,
AS2003, AS2008, AS2010,
AS2011, AS2012, and
AS2014

The post Đ?đầu báo 4?và 6?AS7003-00 | AS7004-00 first appeared on Công ty TNHH Mela.

Bài viết Đ?đầu báo 4″ và 6″ AS7003-00 | AS7004-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/de-dau-bao-4-va-6-as7003-00-as7004-00/feed/ 0
Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-khoi-ong-gio-as5013-as5014/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-khoi-ong-gio-as5013-as5014 //x-zel.com/san-pham/dau-bao-khoi-ong-gio-as5013-as5014/#respond Sat, 07 Nov 2020 03:19:09 +0000 //x-zel.com/?post_type=product&p=1596 The AS5013 and AS5014 are designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke sensors.
?Tải xuống Catalogue

The post Đầu báo khói ống gió AS5013 | AS5014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói ống gió AS5013 | AS5014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Analog Duct Sensors
AS5013-00 and AS5014-00 (with relays)   


Standard Features
?Detects and limits the spread of smoke
throughout building HVAC ducts
?Compatible with building automation
and fire alarm systems
?Installs quickly and easily
?No screens or filters to clean
?Rugged gray steel back box with clear cover
?Accessories – Remote LED alarm indication capability
?Meets UL 268A Requirements

The post Đầu báo khói ống gió AS5013 | AS5014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói ống gió AS5013 | AS5014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-khoi-ong-gio-as5013-as5014/feed/ 0
Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-nhiet-dia-chi-as2010/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-nhiet-dia-chi-as2010 //x-zel.com/san-pham/dau-bao-nhiet-dia-chi-as2010/#respond Sat, 07 Nov 2020 03:12:55 +0000 //x-zel.com/?post_type=product&p=1595 The AS2010 incorporates a highly linear thermistor circuit. The specially designed cover protects the thermistor while allowing maximum air flow. The thermistor circuit produces a voltage proportional to the temperature; this information is transmitted to the control panel as a digital value. When the ambient temperature exceeds a preprogrammed threshold (fixed temp or rate of rise), the sensor transmits an interrupt to the control panel indicating a fire alarm. The fire alarm control panel can adjust the sensor’s fixed temperature threshold for different installation requirements.
Up to 127 devices may be installed on each SLC loop. The sensor address may be set by a hand-held programming unit. The sensor mounts to an electronics-free base and incorporates a locking mechanism for security. The base provides mounting slots, terminals for field wiring and a third terminal for a remote indicator/ LED. The sensor has dual LEDs for easy viewing of the sensor status.
?Tải xuống Catalogue

The post Đầu báo nhiệt địa ch?AS2010 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo nhiệt địa ch?AS2010 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Fixed Temp / Rate of Rise Heat Sensor
AS7010-00  


Standard Features
?Low Profile – Only 2.0?high, including base
?Simple and reliable device addressing method
?Uses the noise immune Digital Communication Protocol
(DCP), which utilizes interrupts for fast response to fires
?Rate of Rise temperature threshold = 15°F/Min (determined by panel)
?Adjustable threshold temperature = 135°F – 190°F (determined by panel)
NOTE Bases are not included with detectors, please order separately

Technical Specifications

Operating Voltage

24 – 41 VDC

Standby Current

350μA

Alarm Current

500μA

Transmission Method

DCP—Digital Communication Protocol

Maximum Humidity

up to 95% non-condensing

UL Temperature Range

135º F to 190º F

Operating Temperature Range

14º F to 122º F

Rate of Rise

15º F Minimum

UL Maximum Spacing

70 feet

Color / Case Material

Bone / ABS Blend

Weight

3.2 oz, (4.9 oz with 4?base)


Ordering Codes

AS2014-00

Multi-Criteria Sensor

AS7001-00

4?Mounting Base

AS7002-00

6?Mounting Base

AS7005-00

6?Low Frequency Sounder Base

The post Đầu báo nhiệt địa ch?AS2010 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo nhiệt địa ch?AS2010 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-nhiet-dia-chi-as2010/feed/ 0
Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-khoi-nhiet-co-ket-hop-dia-chi-as2014/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-khoi-nhiet-co-ket-hop-dia-chi-as2014 //x-zel.com/san-pham/dau-bao-khoi-nhiet-co-ket-hop-dia-chi-as2014/#respond Sat, 07 Nov 2020 03:12:51 +0000 //x-zel.com/?post_type=product&p=1594 The AS2014 smoke detection chamber consists of a light-emitting diode (LED) and photodiode arrangement. The chamber is designed such that light emitted by the LED cannot normally reach the photodiode. In the event of fire, particles of smoke enter the chamber and scatter the light. As the smoke level increases, the scattering effect increases, causing more light to hit the photodiode. The chamber contains a unique design which allows smoke to enter the chamber while preventing external light from affecting the photodiode. The photodiode input level is sampled to sense smoke density. When the smoke density exceeds a pre-set threshold the sensor transmits an interrupt to the fire control panel indicating a fire condition.
The fire alarm control panel can adjust the sensor threshold to compensate for contamination.
The AS2014 heat portion incorporates a highly linear thermistor circuit, with two thermistors mounted externally. The specially designed cover protects the thermistor while allowing maximum air flow. The thermistor circuit produces a voltage proportional to temperature which is scaled, and transmitted as a digitally encoded value to the control panel. When the ambient temperature exceeds a preprogrammed threshold (fixed temperature), the sensor transmits an interrupt to the control panel indicating a fire alarm. The fire alarm control panel can adjust the sensor threshold for different requirements.
The AS2014 CO sensing cell serves a dual purpose of supplementing smoke detection in combination with the photodiode arrangement and monitoring colorless, odorless, and deadly CO levels. When the carbon monoxide exceeds the poisonous levels, the sensor transmits an interrupt to the control panel indicating a CO alarm.
?Tải xuống Catalogue

The post Đầu báo khói ?nhiệt ?CO kết hợp địa ch?AS2014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói – nhiệt – CO kết hợp địa ch?AS2014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Multi-Criteria Sensor – CO, COHb, Smoke, Heat
AS2014-00


Standard Features
?16 Programmable Modes of Operation, based upon 9 different
detection factors allow extreme application flexibility
?Compatible with AS7005 Low Frequency Sounder
base to provide a prioritized Temporal 3 Signal in
case of Fire or Temporal 4 Signal in case of CO
?Simple and reliable device addressing method
?Automatic compensation for sensor contamination
?Built-in fire test feature
?Uses the noise immune Digital Communication Protocol
(DCP), which utilizes interrupts for fast response to fires
?Dual programmable LEDs provide visual alarm / power indications
?Non-directional smoke chamber
?Pre-Alarm Function
?10 year life span on CO sensor

Ordering Codes

AS2014-00

Multi-Criteria Sensor

AS7001-00

4?Mounting Base

AS7002-00

6?Mounting Base

AS7005-00

6?Low Frequency Sounder Base

The post Đầu báo khói ?nhiệt ?CO kết hợp địa ch?AS2014 first appeared on Công ty TNHH Mela.

Bài viết Đầu báo khói – nhiệt – CO kết hợp địa ch?AS2014 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-khoi-nhiet-co-ket-hop-dia-chi-as2014/feed/ 0
Đầu báo cháy địa ch?Avenger - Công ty TNHH Mela //x-zel.com/san-pham/dau-bao-khoi-dia-chi-as2011-00/?utm_source=rss&utm_medium=rss&utm_campaign=dau-bao-khoi-dia-chi-as2011-00 //x-zel.com/san-pham/dau-bao-khoi-dia-chi-as2011-00/#respond Sat, 07 Nov 2020 03:06:39 +0000 //x-zel.com/?post_type=product&p=1592 The detection chamber consists of a light-emitting diode (LED) and photodiode arrangement. The chamber is
designed such that light emitted by the LED cannot normally reach the photodiode. In the event of fire, particles
of smoke enter the chamber and scatter the light. As the smoke level increases, the scattering effect increases, causing more light to hit the photodiode. The chamber contains a unique baffle design which allows smoke to enter the chamber while preventing external light from affecting the photodiode. The photodiode input level is sampled to sense smoke density.
When the smoke density exceeds a preset threshold the sensor transmits an interrupt to the fire control panel
indicating a fire condition. The fire alarm control panel can adjust the sensor threshold to compensate for
contamination.
Up to 127 devices are permitted on each SLC loop. A sensor address is set by a hand-held programming unit.
The sensor mounts to an electronics-free base and incorporates a locking mechanism for secure installation. The base provides mounting slots, terminals for field wiring and a third contact for a remote indicator/LED. The sensor incorporates dual LEDs for easy viewing of sensor status.
?Tải xuống Catalogue

The post Đầu Báo Khói Địa Ch?AS2011-00 first appeared on Công ty TNHH Mela.

Bài viết Đầu Báo Khói Địa Ch?AS2011-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>

Photoelectric Smoke Sensor
AS2011-00


Standard Features
?Low Profile – Only 2?high, including base
?Simple and reliable device addressing
?Automatic compensation for sensor contamination
?Built-in fire test feature
?Uses the noise-immune Digital Communication Protocol
(DCP), which utilizes interrupts for fast response to fires
?Two built-in power/alarm LEDs
?Programmable non-polling LEDs
?Non-directional smoke chamber
?Vandal resistant security locking feature
?Removable smoke labyrinth for cleaning or replacement
NOTE Bases are not included with detectors, please order separately

Ordering Codes

AS2011-00

Photoelectric Smoke Detector

AS7001-00

4?Mounting Base

AS7002-00

6?Mounting Base

AS7008-00

6?Sounder Base

AS7005-00

6?Low Frequency Sounder Base

The post Đầu Báo Khói Địa Ch?AS2011-00 first appeared on Công ty TNHH Mela.

Bài viết Đầu Báo Khói Địa Ch?AS2011-00 đã xuất hiện đầu tiên vào ngày Công ty TNHH Mela.

]]>
//x-zel.com/san-pham/dau-bao-khoi-dia-chi-as2011-00/feed/ 0